Back Button SN75DP120RHHR Datasheet HTML 2Page - Texas Instruments SN75DP120RHHR Datasheet HTML 3Page - Texas Instruments SN75DP120RHHR Datasheet HTML 4Page - Texas Instruments SN75DP120RHHR Datasheet HTML 5Page - Texas Instruments SN75DP120RHHR Datasheet HTML 6Page - Texas Instruments SN75DP120RHHR Datasheet HTML 7Page - Texas Instruments SN75DP120RHHR Datasheet HTML 8Page - Texas Instruments SN75DP120RHHR Datasheet HTML 9Page - Texas Instruments SN75DP120RHHR Datasheet HTML 10Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 27 page
background image
SN75DP120
SLLSE08 – OCTOBER 2009
www.ti.com
Table 1. Description of SN75DP120 Modes
MODE
CHARACTERISTICS
CONDITIONS
ShutDown
Least amount of power consumption (most circuitry turned off);
LP# is low
Mode
HPD_SRC reflects HPD_SINK state, all other outputs are high
impedance and all other inputs are ignored.
DPCD registers and logic are held reset to default values
Standby Mode
Low power consumption; main link inputs and outputs are disabled,
LP# is high;
AUX monitoring is enabled
HPD_SINK low for longer than tT(HPD)
D3 Power
Low power consumption; main link inputs and outputs disabled,
LP# is high;
Down Mode
AUX monitoring is enabled
AUX command requested DP sink to enter D3
power saving mode
Active Mode
Data transfer (normal operation);
LP# is high;
The device is either in TMDS mode (CAD_SINK=high) or DP mode
HPD_SINK is high
(CAD_SINK=low);
HPD_SINK can also be low for less than tT(HPD)
(e.g. sink interrupt request to source)
In DP mode, the AUX monitor is actively monitoring for link training,
Link Training has begun or completed
and the output signal swing, input equalization level and lane count
depend on the link training. At power-up all main link outputs are
disabled by default. AUX Link training is necessary to overwrite the
DPCD registers to enable main link outputs.
In TMDS mode, the output signal swing will be 600mVp-p, and
transactions on the AUX lines will be ignored.
Output Disable DPCD write commands on the AUX bus detected by the SN75DP120
EN is high
Mode
will also write to the local DP120 DPCD register. The local DPCD
DPCD register 101h or 103h entry is invalid
registers should always be written with valid entries. If register 101h or
103h is written with an invalid value, the SN75DP120 disables the
OUTx main link output signals, forcing the DP sink to issue an
interrupt. The DP source can now re-train the link using valid DPCD
register values. As soon as all DPCD registers contain a valid entry,
the SN75DP120 switches back into the appropriate mode of operation.
For a list of valid and invalid DPCD register entries refer to Table 3 and
the DP1.1a specification Table 2-52 and Table 3-12.
Table 2. Transition Between Operational Modes
MODE TRANSITION
USE CASE
TRANSITION SPECIFICS
Shutdown
→ Standby
Activate DP120
1. LP# transitions from low to high
2. Receiver enters Standby mode
3. AUX listener turns on and begins to monitor the AUX
lines
Standby
→ Active
Turn on main link (monitor plugged in)
1. HPD_SINK input asserts high
2. Main link outputs turn on
Active
→ D3
DP source requests temporary power down for
1. Receive D3 entry command on AUX
power savings
2. Main link inputs and outputs are disabled
3. AUX monitor remains active
D3
→ Active
Exit temporary power down
1. AUX channel receives D3 exit command or HPD_SINK
transitions from low to high
2. Enable main link
D3
→ Standby
Exit temporary power down
1. HPD_SINK de-asserted to low for longer than tT(HPD)
Active
→ Standby
turn off main link (monitor unplugged)
1. HPD_SINK de-asserted for longer than tT(HPD)
2. Main link inputs and outputs are disabled
Active/Standby
Turn off DP120
1. LP# pulled low
Shutdown
2. AUX, Main link inputs and outputs are disabled
3. Most IC circuitry is shut down for ultra low power
consumption
4. HPD_SRC reflects HPD_SINK
Any State
→ Output
Invalid DPCD write value to register 101h or 103h
1. OUTx becomes disabled
Disable Mode
6
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): SN75DP120



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com