14 / 19 page ![]() CPC7591 14 www.clare.com R05 2.9 Protection 2.9.1 Diode Bridge/SCR The CPC7591 uses a combination of current limited break switches, a diode bridge/SCR clamping circuit, and a thermal shutdown mechanism to protect the SLIC device or other associated circuitry from damage during line transient events such as lightning. During a positive transient condition, the fault current is conducted through the diode bridge to ground via FGND. Voltage is clamped to a diode drop above ground. During a negative transient of 2 to 4 V more negative than the voltage source at VBAT, the SCR conducts and faults are shunted to FGND via the SCR or the diode bridge. In order for the SCR to crowbar (or foldback), the SCR’s on-voltage (see “Protection Circuitry Electrical Specifications” on page 9) must be less than the applied voltage at the VBAT pin. If the VBAT voltage is less negative than the SCR on-voltage, or if the VBAT supply is unable to source the trigger current, the SCR will not crowbar. For power induction or power-cross fault conditions, the positive cycle of the transient is clamped to a diode drop above ground and the fault current is directed to ground. The negative cycle of the transient will cause the SCR to conduct when the voltage exceeds the VBAT reference voltage by two to four volts, steering the fault current to ground. Note: The CPC7591xB does not contain the protection SCR but instead uses diodes to clamp both polarities of a transient fault. These diodes direct the negative potential’s fault current to the VBAT pin. 2.9.2 Current Limiting function If a lightning strike transient occurs when the device is in the talk state, the current is passed along the line to the integrated protection circuitry and restricted by the dynamic current limit response of the active switches. During the talk state when a 1000V 10x1000 μs lightning pulse (GR-1089-CORE) is applied to the line though a properly clamped external protector, the current seen at TLINE or RLINE will be a pulse with a typical magnitude of 2.5 A and a duration less than 0.5 μs. If a power-cross fault occurs with the device in the talk state, the current is passed though the break switches SW1 and SW2 on to the integrated protection circuit but is limited by the dynamic DC current limit response of the two break switches. The DC current limit specified over temperature is between 80 mA and 425 mA and the circuitry has a negative temperature coefficient. As a result, if the device is subjected to extended heating due to a power cross fault condition, the measured current into TLINE or RLINE will decrease as the device temperature increases. If the device temperature rises sufficiently, the temperature shutdown mechanism will activate and the device will enter the all-off state. 2.10 Thermal Shutdown The thermal shutdown mechanism activates when the device die temperature reaches a minimum of 110 ° C, placing the device in the all-off state regardless of logic input. During thermal shutdown events the TSD pin will output a logic low with a nominal 0 V level. A logic high is output from the TSD pin during normal operation with a typical output level equal to VDD. If presented with a short duration transient such as a lightning event, the thermal shutdown feature will typically not activate. But in an extended power-cross event, the device temperature will rise and the thermal shutdown mechanism will activate forcing the switches to the all-off state. At this point the current measured into TLINE or RLINE will drop to zero. Once the device enters thermal shutdown it will remain in the all-off state until the temperature of the device drops below the de-activation level of the thermal shutdown circuit. This permits the device to autonomously return to normal operation. If the transient has not passed, current will again flow up to the value allowed by the dynamic DC current limiting of the switches and heating will resume, reactivating the thermal shutdown mechanism. This cycle of entering and exiting the thermal shutdown mode will continue as long as the fault condition persists. If the magnitude of the fault condition is great enough, the external secondary protector will activate shunting the fault current to ground. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |