| 数据搜索系统,热门电子元器件搜索 |
|
N4373C 数据表(PDF) 5 Page - Agilent(Hewlett-Packard) |
|
|
|||||||||||||||||||||||||||||
N4373C 数据表(HTML) 5 Page - Agilent(Hewlett-Packard) |
|
5 / 18 page ![]() 5 Definitions Generally, all specifications are valid at the stated operat- ing and measurement conditions and settings, with uninter- rupted line voltage. Specifications (guaranteed) Describes warranted product performance that is valid under the specified conditions. Specifications include guard bands to account for the ex- pected statistical performance distribution, measurement uncertainties changes in performance due to environmental changes and aging of components. Typical values (characteristics) Characteristics describe the product performance that is usually met but not guaranteed. Typical values are based on data from a representative set of instruments. General characteristics Give additional information for using the instrument. These are general descriptive terms that do not imply a level of performance. Explanation of terms Responsivity For electro-optical devices (e.g. modulators ) this describes the ratio of the optical modulated output signal amplitude compared to the RF input amplitude of the device. For opto-electrical devices (e.g. photodiodes) this describes the ratio of the RF amplitude at the device output to the am- plitude of the modulated optical signal input. Relative frequency response uncertainty Describes the maximum deviation of the shape of a mea- sured trace from the (unknown) real trace. This specification has strong influence on the accuracy of the 3-dB cut-off fre- quency determined for the device under test. Absolute frequency response uncertainty Describes the maximum difference between any amplitude point of the measured trace and the (unknown) real value. This specification is useful to determine the absolute re- sponsivity of the device versus modulation frequency. Frequency response repeatability Describes the deviation of repeated measurement without changing any parameter or connection relative to the aver- age of this measurements. Minimum measurable frequency response Describes the average measured responsivity when no mod- ulation signal is present at the device under test. This repre- sents the noise floor of the measurement system. LCA electrical port B LCA optical input LCA optical output LCA electrical port A Definition of LCA input and output names |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |