| 数据搜索系统,热门电子元器件搜索 |
|
D2D 数据表(PDF) 2 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
D2D 数据表(HTML) 2 Page - Omron Electronics LLC |
|
2 / 8 page ![]() 26 Door Interlock Switch D2D Specifications ■ Characteristics Note: 1. Data shown are of initial value 2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate ■ Ratings (Reference values) Note: 1. The above values ar for steady-state current and the motor load has an inrush current of 6 times the steady-state current. 2. The ratings apply under the following test conditions: Ambient Temperature = 20 ±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min. ■ Approved Standards UL Recognized (File No. E41515)( CSA Certified (File No. LR21642) EN61058-1 (File No. 136005 VDE approval) Testing conditions: 1E4 (10,000 operations), T85 (0 °C to 85°C) Note: The value in parentheses indicate motor load ratings. EN61058-1 (File No. R9551934, TÜV Rheinland approval) Testing conditions: 5E4 (50,000 operations), T85 (0 °C to 85°C) ■ Contact Specifications Note: Minimum applicable loads are indicated by N standard refer- ence values. This value represents the failure rate at a 60% (λ 60) reliability level (JIS C5003). The equation λ 60=0.5 x 10 -6 / operations indicates that a failure rate of 1/2,000,000 operations can be expected at a reliability level of 60% Item D2D-1000 models D2D-2000 models D2D-3000 models Operating speed 10 mm/s to 1 m/s Operating frequency Mechanical: 300 operations per minute max. Electrical: 30 operations per minute max. Contact resistance 50 m Ω max. Insulation resistance 100 M Ω min. (at 500 VDC) Dielectric strength 50/60 Hz, 1mm (See note 2) Between terminals of same polarity 2,000 VAC 1,000 VAC 2,000 VAC Between terminals and ground 2,000 VAC 1,500 VAC 2,000 VAC Between terminals and non-current carrying metal parts 2,500 VAC 1,500 VAC - - - Between terminals and actuator 4,000 VAC - - - 4,000 VAC Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude Shock resistance Destruction 1,000 m/s2 (approx 100G) max. Malfunction 500 m/s2 (approx. 50G) max. 300 m/s2 (approx. 30G) max. 500 m/s2 (approx. 50G) max. Degree of protection IEC IP40 Degree of protection vs. electric shock Class II Proof tracking index (PTI) 175 Ambient operating temperature -25 ° to 85°C (at 60% RH max.) with no icing Ambient operating humidity 85% max (for 5 °C to 35°C) Life expectancy Mechanical: 10,000,000 operations min. at 60 operations/minute Electrical: 100,000 operations min. at 30 operations/minute Weight Approx. 14 g (D2D-1000) Resistive load Motor load Type Voltage NC NO NC NO Standard 125 VAC 250 VAC 16 A 4 A Pull-on lock 125 VAC 250 VAC 10 A - - - Rated voltage D2D-1000 D2D-2000 D2D-3000 125 VAC - - - - - - 3/4 hp 250 VAC 16 A 10 A 16A, 1.5 hp Rated voltage D2D-1000 D2D-2000 D2D-3000 250 VAC 16(4) A 10 A 16(4) A Rated voltage D2D-3104 24 VDC 4 A Item Standard model Pull-on lock model Specification Rivet Material Silver Gap (standard value) 3 mm min. 1 mm Inrush current 30 A max. 24 A max. Minimum applicable load (see note) 160 mA at 5 VDC |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |