13 / 42 page ![]() DATA SHEET HAL855 Micronas Nov. 26, 2008; DSH000149_003EN 13 2.3. Calibration Procedure 2.3.1. General Procedure For calibration in the system environment, the applica- tion kit from Micronas is recommended. It contains the hardware for the generation of the serial telegram for programming (Programmer Board Version 5.1) and the corresponding software (PC85x) for the input of the register values. For the individual calibration of each sensor in the cus- tomer application, a two-point adjustment is recom- mended (see Fig. 2–5 on page 14 for an example). The calibration shall be done as follows: Step 1: Input of the registers which need not be adjusted individually The magnetic circuit, the magnetic material with its temperature characteristics, the filter frequency, the part number and the output format are given for this application. Therefore, the values of the following registers should be identical for all sensors of the customer application. –FILTER (according to the maximum signal frequency) –RANGE (according to the maximum magnetic field at the sensor position) – TC and TCSQ (depends on the material of the magnet and the other temperature dependencies of the application) – OUTPUT FORMAT (according to the application requirements) – OUTPUT PERIOD (according to the application requirements) – PARTNUMBER (in case Biphase-M output format is used) – OFFSET CORRECTION –SLEW RATE Write the appropriate settings into the HAL855 regis- ters. Step 2: Initialize DSP As the DIGITAL OUTPUT register value depends on the settings of SLOPE, SHIFT and the OUTPUT CHARACTERISTIC, these registers have to be initial- ized with defined values, first: –ShiftINITIAL = 50% – OUTPUT CHARACTERISTIC = ’Linear Standard’ (Setpoint 0 = 0, Setpoint 1 = 16, Setpoint 2 = 32, ..., Setpoint 31 = 496). – SlopeINITIAL depends on the setting of the digital low-pass filter (see Table 2–8). Step 3: Define Calibration Points For highest accuracy of the sensor, calibration points near the minimum and maximum input signal are rec- ommended. Define nominal values DOUT1NOM and DOUT2NOM of the DIGITAL OUTPUT register at the calibration points 1 and 2, respectively. Note: Micronas software PC85x uses default settings DOUT1NOM = 0 and DOUT2NOM = 3968. The output is clamped to Setpoint 0 and Setpoint 31. In the case of “Linear Standard’”, Setpoint 0 corresponds to DIGITAL OUTPUT = 0, while Setpoint 31 corresponds to DIGITAL OUTPUT = 3968. Table 2–8: Initial slope values −3 dB Frequency SlopeINITIAL 80 0.2578 160 0.2578 500 0.1938 1000 0.1938 2000 0.3398 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |