2
www.honeywell.com/sensing
Table 1. Specifications
Characteristic
Component
Parameter
Sensing range
sensor only
0 mm to 75 mm [0 in to 3.0 in]
Resolution
0,05 mm [0.002 in]
Supply voltage
6 Vdc to 24 Vdc regulated
Output
0 V to 5 V analog
Supply current
32 mA max.
Linearity
±0.4% full scale output
Reverse polarity
26.4 V at 125 °C [257 °F]
Sensitivity
50 mV/mm typ.
Update rate
800 µs
Initial startup time
30 ms
Termination (flying leads)
red = supply voltage, black = ground, green = output
Cable bend radius
40 mm [1.6 in] min.
Operating temperature range
sensor and magnet
-40 °C to 125 °C [-40 °F to 257 °F]
Storage temperature range
-40 °C to 150 °C [-40 °F to 302 °F]
Air gap
3,0 ±2,5 mm [0.118 ±0.098 in]
Magnet velocity along sensor
292 mm/s [11.4 in/s]
Sealing
IP67, IP69K
Shock
50 G half sinewave with 11 ms duration
Vibration
20 G from 10 Hz to 2000 Hz
Housing material
thermoplastic
Approvals
CE
Mounting:
screws
recommended torque range
¼-20 or M6
6 N m to 8 N m [53.1 in lb to 70.8 in lb]
Material
magnet only
neodymium
Strength
10,000 gauss
Note: Percent linearity shall be the quotient of the measured output deviation from the best fit line at the measured temperature to
the full scale output span.
Figure 1. Sensor Output Performance Chart
NOTICE
Ferrous metal within a
100 mm [3.9 in] radius of
the magnet may affect
sensor performance.
Notes:
See Fig. 2 for location of
“L”.
Ideal output at reference point “A” = 0.560 V; ideal output at reference point “B” = 4.31 V.



Html Pages

1 2 3 4


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com