| 数据搜索系统,热门电子元器件搜索 |
|
MPL115A 数据表(PDF) 9 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPL115A 数据表(HTML) 9 Page - Freescale Semiconductor, Inc |
|
9 / 20 page ![]() AN3956 Sensors Freescale Semiconductor 9 Altimetry 1. Alti/Baro Press 2. Waterlevel UPorDN 3. Inertial 4. Additional ‘1’ 1. Altimetry Press a. MPXM2102A UPorDN b. MPL115A2 c. Experimental ‘a’ Raw Value Altitude 0x017c1d 459m 2(LP) value Pressure 0x017c1f 95.365 kPa Select the MPXM2102A, option ‘a’ for higher resolution, amplified pressure readings for Altimetry. Note the way that the output is displayed. The Raw value of the 24-bit ADC value is displayed on the left. The bottom left has the raw value after it passes two low pass filters in software. This value is mores stable but takes longer to update. On the right the Altitude is displayed. This is the pressure converted to altitude in (m). The Pressure corresponding to the ADC value is shown in the bottom right. The board can be placed on the table. Note the Altitude measurement as it stabilizes. Then raise it above your head as a ‘1m’ increase. The value should go up by 1m. Place on the table again. It should drop to the original value. Place on the floor, it will again decrement 1m. Note that ambient pressure from A/C units can affect this value drastically. Barometer Compensated Pressure Output 1. Altimetry Press a. MPXM2102A UPorDN b. MPL115A2 c. Experimental ‘b’ MPL115A2 RawValues Press ADC 74c0 0467 Temp ADC 6b40 0428 ENTER for Coefficients 6 Coefficients ao = 3dc4 c11 = f8a0 b1 = bd7a c12 = 2flc b2 = c299 c22 = 0dc0 Compensated Pressure PComp =9778 kPa Altitude = 365 m The values for the MPL115A are shown here. To the left are the Pressure and Temp ADC values in their raw form in HEX. To the right of them are the shifted values displayed in decimal. Values of the Coefficients are shown here. These are used for the next step in calculating the compensated Pressure. Compensated Pressure is displayed. This is with an accuracy of ±1kPa. Press ENT to continue to the Alarm section. ALARM System Enter your Threshold 0.50 kPa Enter for Activation ALARM sounds when Threshold is reached Press. 96.574 kPa ALARM 97.324 Continued from the MPL115A compensated Barometer section above. Press UP and DN to set the Alarm Threshold in increments of 0.25kPa. Press ENT to activate the Alarm Alarm is now Active. Note the outputs of the current Pressure in kPa, and the Alarm Threshold point. Once crossed, the red LED will flash as the buzzer sounds. Try activating by pressurizing the MPL115A. This can be done with a plastic syringe with rubber tubing at the end to make an air tight fit. ENT ENT ENT ENT ENT ENT ENT |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |