20 / 37 page ![]() DS41393A-Page 16 © 2009 Microchip Technology, Inc. 7.12.11 TouchOptions Register (offset 0x0D) The TouchOptions register contains various “touch” related option bits. R = Readable bit, W = Writable bit, U = Unimplemented bit read as ‘0’ U–0 U–0 U–0 U–0 U–0 U–0 R/W R/W – – – – – – 48W CCE Bit 7 Bit 0 bit 7-2 Unimplemented: Read as ‘0’ bit 1 48W: 4-wire or 8-wire Sensor Selection bit 1 = Selects 8-wire sensor operating mode 0 = Selects 4-wire sensor operating mode bit 0 CCE: Calibrated Coordinates Enable bit 1 = Enables calibrated coordinates, if the controller has been calibrated 0 = Disables calibrated coordinates A 4-wire touch sensor will not work if the 48W configuration bit is incorrectly defined as one, which selects 8-wire. An 8-wire touch sensor will provide basic operation if the 48W configuration bit is incorrectly defined as zero, which selects 4-wire. However, the benefit of the 8-wire sensor will only be realized, if the 48W configuration bit is correctly defined as one, selecting 8-wire. 7.12.12 CalibrationInset Register (offset 0x0E) The CalibrationInset register defines the expected position of the calibration points, inset from the perimeter of the touch sensor’s active area, by a percentage of the full scale dimension. This allows for the calibration targets to be placed inset from edge to make it easier for a user to touch them. The CalibrationInset register value is only used when the Calibration Mode command is issued to the controller. In Calibration Mode, the controller will extrapolate the calibration point touch report values by the defined CalibrationInset percentage to achieve full scale. A software application that issues the Calibration Mode command must present the displayed calibration targets at the same inset percentage as defined in this CalibrationInset register. Valid values are as follows. 0 ≤ CalibrationInset ≤ 40 Calibration Inset = ( CalibrationInset / 2 ) % , Range of 0–20% with 0.5% resolution For example, CalibrationInset = 25 (0x19) yields a calibration inset of (25 / 2) or 12.5%. During the calibration procedure, the controller will internally extrapolate the calibration point touch values in Calibration Mode by 12.5% to achieve full scale. 12.5% of Full Scale 12.5% of Full Scale Location of calibration targets presented during calibration. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |