| 数据搜索系统,热门电子元器件搜索 |
|
NET1-4325 数据表(PDF) 2 Page - Power-One |
|
|
|||||||||||||||||||||||||||||
NET1-4325 数据表(HTML) 2 Page - Power-One |
|
2 / 3 page ![]() NET1 SERIES OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Efficiency Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. 80 % Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Charts Output Power With 300 LFM forced air cooling. (Note 1) 240 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified. See Model Selection Charts input range, changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 10-100% load change, 500 µS 1% max. deviation. Turn-on Delay Time required for initial output voltage stabilization. 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Overvoltage Protection Overvoltage protection on all outputs. Maximum + 0.5V Unit latches off when overvoltage is detected. AC input must be recycled to reset. Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Output Good Open collector global Output Good signal. The signal activates when any of the outputs drop below 5%. Input Power Fail Warning Open collector signal. Time before regulation dropout due to loss of input 5mS power. May be used as independent PSOK signal in redundant applications. Current Share Available on all outputs. Accuracy of shared current with up to 6 parallel units. 10 % Single wire current share. Remote Sense Available on all outputs. Total voltage compensation for cable losses with 500 mV respect to the main output. SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Agency Approvals UL1950. CSA 22.2 NO. 234/950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to output per EN60950. 2600 VDC Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. B Class EN55022 / CISPR 22 Conducted. B ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. ±2 kV Input Transient Protection Per EN61000-4-5, class 3. Line to Line 1 kV Line to Ground 2 Insulation Resistance Input to output. 10 M Advanced Product Release 2 NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |