| 数据搜索系统,热门电子元器件搜索 |
|
ADT7467ARQZ-R7 数据表(PDF) 69 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADT7467ARQZ-R7 数据表(HTML) 69 Page - ON Semiconductor |
|
69 / 77 page ![]() ADT7467 Rev. 3 | Page 69 of 77 | www.onsemi.com Table 37. Register 0x62—Enhanced Acoustics Register 1 (Power-On Default = 0x00) Bit Name R/W1 Description <2:0> ACOU Read/write These bits select the ramp rate applied to the PWM1 output. Instead of PWM1 jumping instantaneously to its newly calculated speed, PWM1 ramps gracefully at the rate determined by these bits. This feature enhances the acoustics of the fan being driven by the PWM1 output. Time Slot Increase Time for 33% to 100% 000 = 1 35 sec 001 = 2 17.6 sec 010 = 3 11.8 sec 011 = 5 7 sec 100 = 8 4.4 sec 101 = 12 3 sec 110 = 24 1.6 sec 111 = 48 0.8 sec <3> EN1 Read/write When this bit is 1, acoustic enhancement is enabled on PWM1 output. <4> SYNC Read/write SYNC = 1 synchronizes fan speed measurements on TACH2, TACH3, and TACH4 to PWM3. This allows up to three fans to be driven from PWM3 output and their speeds to be measured. SYNC = 0 synchronizes only TACH3 and TACH4 to PWM3 output. <5> MIN1 Read/write When the ADT7467 is in automatic fan control mode, this bit defines whether PWM1 is off (0% duty cycle) or at PWM1 minimum duty cycle when the controlling temperature is below its TMIN – hysteresis value. 0 = 0% duty cycle below TMIN – hysteresis. 1 = PWM1 minimum duty cycle below TMIN – hysteresis. <6> MIN2 Read/write When the ADT7467 is in automatic fan speed control mode and the controlling temperature is below its TMIN – hysteresis value, this bit defines whether PWM2 is off (0% duty cycle) or at PWM2 minimum duty cycle. 0 = 0% duty cycle below TMIN – hysteresis. 1 = PWM2 minimum duty cycle below TMIN – hysteresis. <7> MIN3 Read/write When the ADT7467 is in automatic fan speed control mode, this bit defines whether PWM3 is off (0% duty cycle) or at PWM3 minimum duty cycle when the controlling temperature is below its TMIN – hysteresis value. 0 = 0% duty cycle below TMIN – hysteresis. 1 = PWM3 minimum duty cycle below TMIN – hysteresis. 1 This register becomes a read-only register when the Configuration Register 1 LOCK bit is set to 1. Any subsequent attempts to write to this register fail. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |