2 / 4 page

4-88
RF2314
Rev A3 990216
4
Absolute Maximum Ratings
Parameter
Rating
Unit
Supply Voltage
8.0
V
Supply Current
32
mA
Operating Ambient Temperature
-40 to +85
°C
Storage Temperature
-40 to +150
°C
Parameter
Specification
Unit
Condition
Min.
Typ.
Max.
Overall
T=27 °C, VCC=3.0V, Freq=900MHz
Frequency Range
150 to >2500
MHz
NOTE: Lower frequencies can be obtained
with inductive coupling.
3.0V Performance
T=27 °C, VCC=3.0V, Freq=900MHz
Gain
12.9
dB
16.6
dB
Freq=150MHz
7.9
dB
Freq=1900MHz
Noise Figure
1.4
dB
Output IP3
+9.0
dBm
Output P1dB
-1.0
dBm
Input Return Loss
10
dB
Output Return Loss
17
dB
Isolation
20
dB
5.0V Performance
T=27 °C, VCC=5.0V, Freq=900MHz
Gain
14.2
dB
19.1
dB
Freq=150MHz
8.6
dB
Freq=1900MHz
Noise Figure
1.5
dB
Output IP3
+18.0
dBm
Output P1dB
+8.0
dBm
Input Return Loss
13
dB
Output Return Loss
28
dB
Isolation
20
dB
Power Supply
Operating Voltage
2.7 to 6.0
V
Operating Current
5.7
mA
VCC=3.0V
12.5
mA
VCC=5.0V
Caution! ESD sensitive device.
RF Micro Devices believes the furnished information is correct and accurate
at the time of this printing. However, RF Micro Devices reserves the right to
make changes to its products without notice. RF Micro Devices does not
assume responsibility for the use of the described product(s).