| 数据搜索系统,热门电子元器件搜索 |
|
PM2002DP 数据表(PDF) 2 Page - Sames |
|
|
|||||||||||||||||||||||||||||
PM2002DP 数据表(HTML) 2 Page - Sames |
|
2 / 10 page ![]() sames sames PM2002DP 2/10 http://www.sames.co.za MODULE SETUP The PM2002DP module is setup for use with the SA2002D integrated circuit. Resistor values used on the module are calculated for rated conditions of 80A/220V. IIN IIP Vref R2 R1 R0 FAST Vdd CNF NC AGND IVP DIRI DIRO NC MON Vss LED MOP NC P4 P5 P6 P7 P8 P9 P10 J3 P17 P16 P15 P14 P13 P12 P11 P18 J4 Vdd Vss J15 Vdd Vss J14 Vdd Vss J13 Vdd Vss J12 Vdd Vss J11 Vdd Vss J1 J2 1 2 JP3 Vss J6 6 5 4 3 2 1 . 1 SA2002D Figure 2: Jumper schematic, digital IO’s Name Function Description J1 J1 is used to select the energy direction ( DIRI pin). The three options available are: P18 connected to Vdd - Negative energy measurement P18 connected to Vss - Positive energy measurement P18 connected to J2 (P17) - Bi-directional energy measurement P18 should not be left floating and must be connected to one of the options described above. J2 J2 is only used to select bi-directional energy measurement when connected to P18 J3 and J4 These are test points placed next to the digital pins of the SA2002E J5 Not fitted This is the current sense input ground. If a current transformer is used for current sensing the two pins of J5 must be connected. J6 Connects the impulse to VSS. If a stepper motor is connected to JP3 then J6 should be left open. J7 Analog ground test point (see figure 1) J8 Positive supply test point (Vdd) (see figure 1) J9 Negative supply test point (Vss) (see figure 1) J11, J12 and J13 Used to select the R2, R1 and R0 pins of the SA2002D for the various rated conditions. Refer to table 1 for the possible settings J14 Used to select fast calibration mode. Connecting P7 to Vdd selects fast calibration mode. For normal operation P7 must be connected to Vss J15 Used to select between normal and configure / test modes. For normal operation connect P9 to Vss. J16 Used to select between 220V and 110V mains systems (See figure 3). Leave open for 220V mains. Table 3: Jumper settings for various device options |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |