10 / 16 page ![]() SA9103C sames 10/16 8. Calibration For the calibration of the SA9103C, the following procedure is recommended: a. Establish calibration factor for active energy (Ka) at pf close to 1. Active (Measured) = register_value (Active) * Ka. 1 b. The factor for reactive (Kr) is typically Ka * PI/2. For higher accuracy of Kr, establish Kr at pf close to 0. Reactive (Measured) = register_value (Reactive) * Kr 2 c. At pf close to 1, establish error for reactive (Er) Er = (Reactive (Measured) - Reactive (True)) / Active (Measured) 3 Reactive (Corrected) = Reactive (Measured) - Er * Active (Measured) 3b Measurement Having determined the scaling factors (Ka & Kr) and error correction constant (Er) the measurement cycle consists of the following steps: step 1 Read active register step 2 Calculate Active (Measured) as per 1 Active energy step 3 Read reactive register step 4 Calculate Reactive (Measured) as per 2 step 5 Perform error correction Calculate Reactive (Corrected) as per 3b Reactive energy The above five steps must be performed for each measurement cycle. ∨∨∨∨∨ ∨∨∨∨∨ ∨∨∨∨∨ ∨∨∨∨∨ ⇒ ⇒ ⇒ ⇒ ⇒ ⇒ ⇒ ⇒ ⇒ ⇒ |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |