数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

SA9105EPA 数据表(PDF) 7 Page - Sames

部件名 SA9105EPA
功能描述  THREE PHASE UNIDIRECTIONAL POWER/ENERGY METERING IC WITH INSTANTANEOUS PULSE OUTPUT
PDF  12 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  SAMES [Sames]
网页  http://www.sames.co.za
标志 SAMES - Sames

SA9105EPA 数据表(HTML) 7 Page - Sames

Back Button SA9105EPA Datasheet HTML 3Page - Sames SA9105EPA Datasheet HTML 4Page - Sames SA9105EPA Datasheet HTML 5Page - Sames SA9105EPA Datasheet HTML 6Page - Sames SA9105EPA Datasheet HTML 7Page - Sames SA9105EPA Datasheet HTML 8Page - Sames SA9105EPA Datasheet HTML 9Page - Sames SA9105EPA Datasheet HTML 10Page - Sames SA9105EPA Datasheet HTML 11Page - Sames Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 12 page
background image
SA9105E
sames
sames
sames
sames
sames
43/12
TYPICAL APPLICATION
In the Application Circuit (Figure 1), the components required for a three phase power
metering application are shown. Terminated current transformers are used for current
sensing.
The most important external components for the SA9105E integrated circuit are:
C
7, C9, C10 and C11 are the outer loop capacitors for the integrated oversampling
A/D converters. The typical value of C
7 is 2.2nF and the value of C9, C10 and C11 is
560pF.
The actual values determine the signal to noise and stability performance. The tolerances
should be within ± 10%.
C
4, C5, C6 and C8 are the inner loop capacitors for the integrated oversampling A/D
converters. The typical value of C
4, C5, C6 and C8 is 3.3nF. Values smaller than 0.5nF
and larger than 5nF should be avoided.
Terminated current sensors (current transformers) are connected to the current sensor
inputs of the SA9105E through current setting resistors (R
8 ..R13).
The resistor values should be selected for an input current of 16
µA into the SA9105E, at
the rated line current.
The values of these resistors should be calculated as follows:
Phase 1:
R
8 = R9 = (IL1/16µA) * R18/2
Phase 2:
R
10 = R11 = (IL2/16µA) * R19/2
Phase 3:
R
12 = R13 = (IL3/16µA) * R20/2
Where I
LX
=
Secondary CT current at rated conditions.
R
18, R19 and R20
=
Current transformer termination resistors for the three phases.
R
1 + R1A, R4 and R15 set the current for the phase 1 voltage sense input.
R
2 + R2A, R5 +
P
5 and R16 set the current for phase 2 and R3 + R3A, R6 + P6 and R17 set the current for phase
3. The values should be selected so that the input currents into the voltage sense inputs
(virtual ground) are set to 14
µA for nominal line voltage. Capacitors C1, C2 and C3 are
for decoupling and phase compensation.
R
14 + P14 defines all on-chip bias and reference currents. With R14+ P14 = 24kΩ, optimum
conditions are set. R
14 may be varied within ± 10% for calibration purposes. Any changes
to R
14 will affect the output quadratically (i.e:
∆R = +5%, ∆f = +10%).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com