| 数据搜索系统,热门电子元器件搜索 |
|
SC643 数据表(PDF) 14 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC643 数据表(HTML) 14 Page - Semtech Corporation |
|
14 / 26 page ![]() SC643 14 Table 1 — Fade-In from Off State Command Sequence Action Data Disable fade for the bank 1. Write to register 09h 00h Set the bank to 0.5mA 2. Write to register 01h and/or 02h(1) 04h Enable fade 3. Write to register 09h Binary value xx1xx0, xx1xx1, or xx0xx1 Set BLEN bits 4. Write to register 00h Any value from 01h through 1Fh Set new value of backlight current for the bank 5. Write to register 01h and/or 02h Any value from 05h through 1Fh Notes: (1) Write only to the banks which will fade Fade-Out from any On State to Off State Fading the backlight LEDs from any active state to the off state follows a simple procedure. The sequence of com- mands for this action is shown in Table 2. Following these steps explicitly will ensure that the fade-out operation will proceed with no interruption at the rate specified in the Main/Sub Backlight Fade register (09h). This procedure must be followed regardless of the backlight grouping configuration. Table 2 — Fade-Out from any On State to Off State Command Sequence Action Data Enable fade 1. Write to register 09h Any value from 01h through 3Fh (but not 00h) Set Main and/or Sub backlights to 0mA 2. Write to register 01h and/or 02h 00h Fading Between Different On States Fading from one backlight level to another (up or down) also follows a simple procedure. The sequence of com- mands for this action is shown in Table 3. Following these Applications Information (continued) steps explicitly will ensure that the fade-in/fade-out oper- ation will proceed with no interruption at the rate specified in the Main/Sub Backlight Fade register (09h). This proce- dure must be followed regardless of the backlight grouping configuration. Table 3 — Fading between Different On States Command Sequence Action Data Enable fade 1. Write to register 09h Any value from 01h through 3Fh (but not 00h) Set new value of backlight current 2. Write to register 01h and/or 02h Any value from 05h through 1Fh Additional Information For more details about the Fade-in/Fade-out function, refer to the SC643 Backlight Driver Software User’s Guide and SemPulse Interface Specification document and to the associated software drivers available for this device (contact your sales office for more details). Programmable LDO Outputs Four low dropout (LDO) regulators are included to supply power to peripheral circuits. Each LDO output voltage setting has ±3.5% accuracy over the operating tempera- ture range. Output current greater than specification is possible at somewhat reduced accuracy (refer to the typical characteristic section of this datasheet for load regulation examples). LDO1, LDO3, and LDO4 have iden- tical specifications, with a programmable output ranging from 1.5V to 3.3V. LDO2 is specified to operate with pro- grammable output ranging from 1.2V to 1.8V. LDO2 also has lower noise specifications so that it can be used with noise sensitive circuits. LDO4 is controlled by both the enable pin ENL4 and the LDO4 control register. ENL4 may be permanently con- nected to V IN for software-only control. Alternately, power sequencing logic may be used to enable LDO4 via the ENL4 pin after writing to the LDO4 control register. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |