14 / 22 page ![]() 4 SC657 SemPulseTM Interface Introduction SemPulse is a write-only single wire interface. It provides the capability to access up to 32 registers that control device functionality. Two sets of pulse trains are transmit- ted via the SPIF pin. The first pulse set is used to set the desired address. After the bus is held high for the address hold period, the next pulse set is used to write the data value. After the data pulses are transmitted, the bus is held high again for the data hold period to signify the data write is complete. At this point the device latches the data into the address that was selected by the first set of pulses. See the SemPulse Timing Diagrams for descriptions of all timing parameters. Chip Enable/Disable The device is enabled when the SemPulse interface pin (SPIF) is pulled high for greater than t SU. If the SPIF pin is pulled low again for more than t SD, the device will be disabled. Address Writes The first set of pulses can range between 0 and 3 (or to 32 rising edges) to set the desired address. After the pulses are transmitted, the SPIF pin must be held high for t HOLDA to signal to the slave device that the address write is finished. If the pulse count is between 0 and 3 and the line is held high for t HOLDA, the address is latched as the destination for the next data write. If the SPIF pin is not held high for t HOLDA, the slave device will continue to count pulses. Note that if t HOLDA exceeds its maximum specifica- tion, the bus will reset. This means that the communication is ignored and the bus resumes monitoring the pin, expecting the next pulse set to be an address. If the total exceeds 3 pulses, SPIF must be held high until the bus reset time t BR i s e xce e d e d b e fo re co m m e n c i n g communication. Data Writes After the bus has been held high for the minimum address hold period, the next set of pulses are used to write the data value. The total number of pulses can range from 0 to 63 (or to 64 rising edges) since there are a total of 6 register bits per register. Just like with the address write, the data write is only accepted if the bus is held high for t HOLDD when the pulse train is completed. If the proper hold time is not received, the interface will keep counting pulses until the hold time is detected. If the total exceeds 63 pulses, the write will be ignored and the bus will reset after the next valid hold time is detected. After the bus has been held high for t HOLDD, the bus will expect the next pulse set to be an address write. Note that this is the same effect as the bus reset that occurs when t HOLDA exceeds its maximum specification. For this reason, there is no maximum limit on t HOLDD — the bus simply waits for the next valid address to be transmitted. Multiple Writes It is important to note that this single-wire interface requires the address to be paired with its corresponding data. If it is desired to write multiple times to the same address, the address must always be re-transmitted prior to the corresponding data. If it is only transmitted one time and followed by multiple data transmissions, every other block of data will be treated like a new address. The result will be invalid data writes to incorrect addresses. Note that multiple writes only need to be separated by the minimum t HOLDD for the slave to interpret them cor- rectly. As long as t HOLDA between the address pulse set and the data pulse set is less than its maximum specification but greater than its minimum, multiple pairs of address and data pulse counts can be made with no detrimental effects. Standby Mode Once data transfer is completed, the SPIF line must be returned to the high state for at least 0ms to return to the standby mode. In this mode, the SPIF line remains idle while monitoring for the next command. This mode allows the device to minimize current consumption between commands. Once the device has returned to standby mode, the bus is automatically reset to expect the address pulses as the next data block. This safeguard is intended to reset the bus to a known state (waiting for the beginning of a write sequence) if the delay exceeds the reset threshold. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |