| 数据搜索系统,热门电子元器件搜索 |
|
ARH2805S/CK 数据表(PDF) 10 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
ARH2805S/CK 数据表(HTML) 10 Page - International Rectifier |
|
10 / 12 page ![]() 10 www.irf.com ARH28XXS Series Radiation Performance The radiation tolerance characteristics inherent in the ARH28XXS converters are a result of a carefully planned ground-up design program with specific radiation design goals. Identification of the general circuit topology, a fundamental task in the design effort, was followed by selection of appropriate elements from a list of devices for which extensive radiation effects data was available. By imposing sufficiently large margins on those electrical parameters showing the worst case degrading effects of radiation, designers were able to select appropriate elements for incorporation into the circuit. Existing radiation data was utilized for input to PSPICE and RadSPICE in the generation of circuit performance verification analyses. Thus, electrical performance capability under all environmental conditions including radiation was well understood before first application of power to the inputs. The following table specifies guaranteed minimum radia- tion exposure levels tolerated while maintaining specifica- tion limits. A principal design goal was achieving a converter topol- ogy that, because of large design margins, had radiation performance essentially independent of radiation induced element-lot performance variations. Where such margins cannot be assured, element lots are either selected fol- lowing RLAT characterization as radiation hard devices or, purchased as radiation hard devices so that realization of the design goals are maintained. . Test Conditions Min Typ Max Unit Total Ionizing Dose (2:1 Margin) MIL-STD-883, Method 1019.4 Operating bias applied during exposure 100 500 Krads (Si) Dose Rate Temporary Saturation Survival MIL-STD-883, Method 1021 1E8 1E11 Rads (Si)/sec Heavy Ions (Single event effects) BNL Dual Van de Graf Generator 83 MeV• cm²/mg Radiation Specification T case = 25°C International Rectifier currently does not have a DSCC certified Radiation Hardness Assurance Program. * Group B quantity for option 2 End of Line QCI. No Group B samples required for Option 1, In-line. Inspection Application Samples Group A Part of Screening on Each Unit 100% Group B Each Inspection Lot * 5 units Group C First Inspection Lot or Following Class 1 Change 10 units Group D In Line (Part of Element Evaluation) 3 units Standard Quality Conformance Inspections on ARH28XXS Series (Filght Screened) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |