| 数据搜索系统,热门电子元器件搜索 |
|
MPL015A2 数据表(PDF) 2 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPL015A2 数据表(HTML) 2 Page - Freescale Semiconductor, Inc |
|
2 / 8 page ![]() MPL015A2 Sensors 2 Freescale Semiconductor Pressure Maximum Ratings Voltage (with respect to GND unless otherwise noted) VDD .............................................................................................................................. -0.3 V to +5.5 V SCLK, CS, DIN, DOUT ................................................................................................. -0.3 V to VDD+0.3 V Operating Temperature Range .................................................................................... -40°C to +105°C Storage Temperature Range........................................................................................ -40°C to +125°C Overpressure ............................................................................................................... 1000 kPa Operating Characteristics (VDD = 2.375 V to 5.5 V, TA = -40°C to +105°C, unless otherwise noted. Typical values are at V+ = 3.3 V, TA = +25°C. Ref Parameters Symbol Conditions Min Typ Max Units 1 Operating Supply Voltage VDD 2.375 3.3 5.5 V 2 Supply Current IDD Shutdown (SHDN = GND) @ 25ºC — 0.06 1 μA Standby — 3.5 10 μA Average – at one measurement per second — 5 6 μA Pressure Sensor 3 Range 50 — 115 kPa 4 Resolution —0.15 — kPa 5 Accuracy @ 25ºC — ±1 — kPa 6 Accuracy Change over Temperature — ±0.125 — kPa/ºC 7 Power Supply Rejection Typical operating circuit at DC — 0.1 — kPa/V 100 mV p-p 217 Hz square wave plus 100 mV pseudo random noise with 10 MHz bandwidth. —0.1 — kPa 8 Conversion Time (Start Pressure Convert) tcp Time between start convert command and data available in the Pressure register —0.6 0.7 ms Temperature Sensor 9 Range -40 — 105 ºC 10 Conversion Time (Start Temperature Convert) tct Time between start convert command and data available in the Temperature register —0.6 0.7 ms 11 Conversion Time (Start Both Convert) tcb Time between start convert command and data available in the Pressure and Temperature registers —0.8 1 ms 12 Resolution Temperature ADC is 472 counts @ 25ºC — -5.35 — counts/ºC I2C I/O Stages: SCL, SDA 13 SCL Clock Frequency fSCL — — 400 KHz 14 Low Level Input Voltage VIL — — 0.3VDD V 15 High Level Input Voltage VIH 0.7VDD —— V I2C Outputs: SDA 16 Data Setup Time tSU Setup time from command receipt to ready to transmit 100 — — ns I2C Addressing MPL015A2 uses 7-bit addressing, does not acknowledge the general call address 0000000. Slave address has been set to 0x60 or 1100000. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |