XRP7713 数据表(PDF) 3 Page - Exar Corporation

部件名 XRP7713
功能描述  Three Channel Digital PWM Step Down Controller
PDF  29 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  EXAR [Exar Corporation]
网页  http://www.exar.com
标志 EXAR - Exar Corporation

XRP7713 数据表(HTML) 3 Page - Exar Corporation

  XRP7713 Datasheet HTML 1Page - Exar Corporation XRP7713 Datasheet HTML 2Page - Exar Corporation XRP7713 Datasheet HTML 3Page - Exar Corporation XRP7713 Datasheet HTML 4Page - Exar Corporation XRP7713 Datasheet HTML 5Page - Exar Corporation XRP7713 Datasheet HTML 6Page - Exar Corporation XRP7713 Datasheet HTML 7Page - Exar Corporation XRP7713 Datasheet HTML 8Page - Exar Corporation XRP7713 Datasheet HTML 9Page - Exar Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 29 page
background image
X
XR
RP
P7
77
71
13
3
T
Th
hrreeee C
Ch
ha
an
nn
neell D
Diig
giitta
all P
PW
WM
M S
Stteep
p D
Do
ow
wn
n C
Co
on
nttrro
olllleerr
© 2010 Exar Corporation
3/29
Rev. 1.1.1
Low Drop-out Regulator
Parameter
Min.
Typ.
Max.
Units
Conditions
LDOOUT Output Voltage
LDO=LOW
3.15
3.3
3.45
V
• 4.75V≤VIN≤25V
0mA<ILDOOUT<100mA
LDOOUT Output Voltage
LDO=HIGH
4.75
5.0
5.25
V
• 6.3≤VIN≤25V
0mA<ILDOOUT<100mA
LDOOUT Short Circuit Current
Limit
110
220
mA
• VLDOOUT=0V
Auxiliary ADCs
Parameter
Min.
Typ.
Max.
Units
Conditions
Linearity Error Integral
2
LSB
Linearity Error Differential
-1
1
LSB
Input Dynamic Range VIN
4.8
25
V
Isense ADC
Parameter
Min.
Typ.
Max.
Units
Conditions
ADC LSB
5
mV
Referred to the input
Input Dynamic Range
0
-320
mV
PWM Generators and Oscillator
Parameter
Min.
Typ.
Max.
Units
Conditions
Output frequency range
300
1500
kHz
Steps defined in the table in the PWM
Switching Frequency Setting section
below
Output Frequency Accuracy
-10
10
%
Channel-to-channel phase shift
90
deg
Minimum On Time
40
ns
1nF of gate capacitance
Dead Time Adjustment Step
13
ns
Switching frequency = 300kHz
10% to 90% duty cycle, Frequency
dependant; refer to the graph in
performance characteristic section
1.5
ns
Switching frequency = 1.5MHz
10% to 90% duty cycle, Frequency
dependant; refer to the graph in
performance characteristic section
CLOCK IN Synchronization
Range
-5
5
%
Maximum Duty Cycle2
86
%
• Switching frequency = 300kHz
78
%
• Switching frequency = 1.5MHz
Note 2: The maximum duty cycle represents the maximum duty cycle commanded by the DPWM, is guaranteed by design,
and internally set to ensure proper sampling of the current during the off-time.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com