| 数据搜索系统,热门电子元器件搜索 |
|
MS18-1006 数据表(PDF) 2 Page - Tyco Electronics |
|
|
|||||||||||||||||||||||||||||
MS18-1006 数据表(HTML) 2 Page - Tyco Electronics |
|
2 / 2 page ![]() 2 MS18-1006 High Performance Solid State Relay DC & bi-directional solid state relay for loads up to 2A @ 80Vdc Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-3611-1514 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013 www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-5-729-0425 UK: 44-141-810-8967 Figure 2 - Temperature Derating Curves Series Configuration Parallel Configuration AMBIENT TEMPERATURE ( °C) 5 152535 4555 6575 8595 105 115 125 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 5 152535 4555 6575 8595 105 115 125 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 AMBIENT TEMPERATURE ( °C) Figure 3 - Turn-on and Turn-off Timing Figure 4 - Functional Block Diagram PIN 1 REF TO 2 PIN 6 TO 4 T(ON) T(ON) HIGH LOW OFF ON 90% 10% FLOATING POWER SUPPLY TIMING & SIGNAL COND. BIAS RTN CASE GND 1 3 2 LINE RTN LINE 6 4 5 Figure 5 - Outline Dimensions 0.190 MAX. (4.83) 0.160 (4.06) MIN. 0.463 MAX. (11.76) 0.300 (7.62) DATE CODE ON THIS SURFACE 0.020 MAX. (0.508) 6 PLS 0.017 +.002, –.001 (0.432 +.051, –.025) 0.084 ±.005 (2.13 ± .127) 0.109 (2.77) 0.200 (5.08) 0.100 (2.54) 0.418 (10.62) MS18-TBD–PDF–KRG–1-04 Notes 1. An external resistor must be in series with the input at all times. 2. Do not ramp input current. Input transition should be <1.0ms. 3. Input current/series resistor calculation (Approx.): I(input) = VIN – VDROP/RSERIES. 4. Unless otherwise specified parametric testing is accomplished at 25ma input current. 5. To calculate RDS(ON) for tempertures other than 25°C, use the following equation: T(TEMP) = (RDS(ON) at + 25°C) • e(X • ∆T) where x = 0.0065. 6. Inductive loads must be diode suppressed. 7. Continuous load current is rated under conditions of still air. 8. Load may be connected to either side of relay, sink or source modes. 9. Reverse polarity >5Vdc may cause permanent damage 10. Acceptance testing is accomplished in the series (bi-directional) mode. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |