| 数据搜索系统,热门电子元器件搜索 |
|
WOUVT 数据表(PDF) 1 Page - Tyco Electronics |
|
|
|||||||||||||||||||||||||||||
WOUVT 数据表(HTML) 1 Page - Tyco Electronics |
|
|
1 / 1 page ![]() Function: 24 Tyco Electronics / www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International) • ANSI/IEEE C37.90-1978 Voltage sensitive relays are available for both AC and DC applications for overvoltage and undervoltage protection. Combination over/undervoltage relays provide band-pass capabilities. AC relays are either single or three-phase type. Three phase relays are designed to sense the average of the three phases. Voltage trip points are screwdriver adjustable, and operation is time-delayed so that momentary volt- age transients will not cause nuisance tripping. Operation: The relay will energize at normal voltage condition. The normally closed contact (Form B) will open and the normally open (Form A) will close. The relay will de-energize after time delay when over or undervoltage condition is reached. Voltage Sensitive Relays PRODUCT SPECIFICATIONS Sample Part No. WOUVT -1-120AC Type: WOUVT - Over/Undervoltage No. Phases 1 = Single 3 = Three (line to line) Line Voltage VAC 115 120 200 208 220 230 240 380 Options: Blank - Standard A = 2 Form A Contacts B = 2 Form B Contacts H = 125 VDC Contacts P = Transient Protection Option "H" provides for contacts rating of 3 amps @ 125VDC. Option "P" provides additional transient protection which complies with the requirements of ANSI/IEEE C37.90- 1978 Consult factory for additional models. Notes: 1. Remove black screw for access to the voltage trip and time delay adjustment potentiometer. 2. Clockwise rotation of the voltage adjustment potentiometer will raise the voltage trip point. 3. Clockwise rotation of the time adjustment potentiometer will increase the drop-out time delay. PART NUMBER SELECTION Part Number Nominal Voltage ............................... Phase ................................................ Line Frequency ................................. Type of Sensing ............................... Undervoltage Trip ............................ Overvoltage Trip ............................... Drop-out Time Delay ........................ Pick-up to Drop-out Differential ...... Output Contacts ............................... Contact Ratings ................................ Operating Temperature Range ........ Power Consumption ........................ WOUVT 120 VAC to 575 VAC Single or Three 50-400 Hz Average of all three phases 70-100% of nominal voltage, screwdriver adjustable 100-125% of nominal voltage, screwdriver adjustable 0.5 to 20 seconds, screwdriver adjustable 2% maximum One set N.O., One set N.C. 5 amp resistive at 120 VAC or 28 VDC -40 °C to +70°C 4 VA maximum 400 416 440 460 480 525 575 11 /64" DIA. 4 MTG. HOLES 3.0 TERMINAL STRIP #6 - 32 SCREWS 3 1 /2 4 1 /4 27/59 WILMAR™ Protective Relays – WOUVT Series, Over/Undervoltage Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. |
类似零件编号 - WOUVT |
|
类似说明 - WOUVT |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |