| 数据搜索系统,热门电子元器件搜索 |
|
WSYN 数据表(PDF) 1 Page - Tyco Electronics |
|
|
|||||||||||||||||||||||||||||
WSYN 数据表(HTML) 1 Page - Tyco Electronics |
|
|
1 / 1 page ![]() Function: 38 Tyco Electronics / www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International) • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 Operation: A. The output relay will energize when all three of the following conditions are met: 1. Voltage differential is below the preset value. 2. Phase angle is below the preset value. 3. Frequency differential is below the preset value. B. The relay is also provided with a "Double Dead Bus" feature: When the voltage on either one of the sensing inputs is below 15-25% of nominal, (Dead Bus Condition), the output relay will energize to permit paralleling. When both sensing voltage are below 15-25% of nominal, the output relay will not energize. Paralleling Relays PRODUCT SPECIFICATIONS Part Number Sensing Voltage ................................... Control Voltage .................................... Voltage Differential Adjust Range ....... Phase Angle Adjust Range .................. Frequency Differential Adjust Range Operating Temperature ........................ Contact Ratings .................................... Output Contacts ................................... WSYN Series Single Phase, see Part Number Selection See Part Number Selection 4% to 10% of nominal voltage 4 to 10 electrical degrees 0.2 Hz to 0.5 Hz -20o C to +50 oC 5 amp resistive at 120 VAC or 28Vdc One set N.O., one set N.C. Sample Part No. WSYN-50-120-12DC-A Type: WSYN - Synchro Check Frequency Hz 50 60 400 Sensing Voltage VAC ( ±10%) 120 400 200 416 208 440 220 460 230 480 240 525 380 575 Control Voltage ( ±20%) 12DC 120AC 24DC 230AC 48DC 380AC 125DC 460AC Options A = two normal open contacts B = two normally closed contacts H = Contacts rated 3 amp at 125 VDC P = Transient Protection Transient Protection - All voltage relays will withstand momentary voltage surges of twice the nominal rated input voltage (standard). PART NUMBER SELECTION Notes: 1. Remove black cover screws to gain access to the adjustment potentiometers. 2. Clockwise rotation increases the trip differential setting. 3. Calibration terminals (11) (12) must be connected together to disable the phase angle detector when setting the frequency difference trip point. Once it is set, the connection must be removed. 13 /64" DIA. 4 MTG. HOLES 3 1/2 4 3/16 TERMINAL STRIPS #6 - 32 SCREWS 4 1 /2 5 15 /32 25 WILMAR™ Protective Relays – WSYN Series Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. |
类似零件编号 - WSYN |
|
类似说明 - WSYN |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |