| 数据搜索系统,热门电子元器件搜索 |
|
71M6543F 数据表(PDF) 21 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
71M6543F 数据表(HTML) 21 Page - Maxim Integrated Products |
|
21 / 157 page ![]() 71M6543F/H and 71M6543G/GH Data Sheet v1.2 © 2008–2011 Teridian Semiconductor Corporation 21 Figure 6: General Topology of a Chopped Amplifier It is assumed that an offset voltage Voff appears at the positive amplifier input. With all switches, as controlled by CROSS (an internal signal), in the A position, the output voltage is: Voutp – Voutn = G (Vinp + Voff – Vinn) = G (Vinp – Vinn) + G Voff With all switches set to the B position by applying the inverted CROSS signal, the output voltage is: Voutn – Voutp = G (Vinn – Vinp + Voff) = G (Vinn – Vinp) + G Voff, or Voutp – Voutn = G (Vinp – Vinn) - G Voff Thus, when CROSS is toggled, e.g., after each multiplexer cycle, the offset alternately appears on the output as positive and negative, which results in the offset effectively being eliminated, regardless of its polarity or magnitude. When CROSS is high, the connection of the amplifier input devices is reversed. This preserves the overall polarity of that amplifier gain; it inverts its input offset. By alternately reversing the connection, the amplifier’s offset is averaged to zero. This removes the most significant long-term drift mechanism in the voltage reference. The CHOP_E[1:0] (I/O RAM 0x2106[3:2]) control field controls the behavior of CROSS. On the first CK32 rising edge after the last multiplexer state of its sequence, the multiplexer waits one additional CK32 cycle before beginning a new frame. At the beginning of this cycle, the value of CROSS is updated according to the CHOP_E[1:0] field. The extra CK32 cycle allows time for the chopped VREF to settle. During this cycle, MUXSYNC is held high. The leading edge of MUXSYNC initiates a pass through the CE program sequence. CHOP_E[1:0] has four states: positive, reverse, and two toggle states. In the positive state, CHOP_E[1:0] = 01, CROSS is held low. In the reverse state, CHOP_E[1:0] = 10, CROSS is held high. The two automatic toggling states are selected by setting CHOP_E=11 or CHOP_E=00. Figure 7: CROSS Signal with CHOP_E = 00 Figure 7 shows CROSS over two accumulation intervals when CHOP_E[1:0] = 00: At the end of the first interval, CROSS is high, at the end of the second interval, CROSS is low. Operation with CHOP_E[1:0] = 00 does not require control of the chopping mechanism by the MPU. In the second toggle state, CHOP_E[1:0] = 11, CROSS does not toggle at the end of the last multiplexer cycle in an accumulation interval. G - + V inp V outp V outn V inn CROSS A B A B A B A B |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |