21 / 34 page ![]() TLE4998P Signal Processing Data Sheet 21 V 1.0, 2008-07 6.5 Clamping The clamping function is useful for splitting the output voltage range into operating range and error ranges. If the magnetic field is outside the selected measurement range, the output value OUT is limited to the clamping values. The clamping values are calculated by: Clamping duty cycle low (deactivated if CL=0): Clamping duty cycle high (deactivated if CH=127): Table 13 Clamping Parameter Symbol Limit Values Unit Notes min. max. Register size CL,CH 2 x 7 bit Clamping duty cy. low CYCLPWM 0 100 % 1) 1) For CL = 0 and CH = 127 the clamping function is disabled Clamping duty cy. high CYCHPWM 0 100 % 1) 2) 2) CY CLPWM< CYCHPWM mandatory Clamping quantization steps ∆CY CxPWM 0.78 % 3) 3) Quantization starts for CL at 0% and for CH at 100% CY CLPWM CL 32 ⋅ 4096 ------------------ = CY CHPWM CH 1 + () 32 1 – ⋅ 4096 ---------------------------------------- = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|