| 数据搜索系统,热门电子元器件搜索 |
|
CS1501-FSZ 数据表(PDF) 9 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS1501-FSZ 数据表(HTML) 9 Page - Cirrus Logic |
|
9 / 11 page ![]() CS1501 DS927PP6 9 5. GENERAL DESCRIPTION The CS1501 offers numerous features, options, and functional capabilities to the designer of switching power converters. This digital PFC control IC is designed to replace legacy analog PFC controllers with minimal design effort. 5.1 PFC Operation One key feature of the CS1501 is its operating frequency profile. Figure 11 illustrates how the frequency varies over one half cycle of the line voltage in steady-state operation. When power is first applied to the CS1501, it examines the line voltage and adapts its operating frequency to the line voltage as shown in Figure 11. The operating frequency is varied from the peak to the trough of the AC input. During startup, the control algorithm generates maximum power while operating in critical conduction mode (CRM), providing an approximate square-wave current envelop within every half-line cycle. Figure 11. Switching Frequency vs. Phase Angle Figure 12 illustrates how the operating frequency (as a percentage of maximum frequency) changes with output power and the peak of the line voltage. Figure 12. Max. Switching Frequency vs. Output Power When PO falls below 5%, the CS1501 changes to Burst Mode. (Refer to Burst Mode section for more information.) The CS1501 is designed to function as a DCM controller. However, during peak periods, the controller may interchange control methods and operate in a quasi-critical-conduction mode (quasi-CRM) at low line. For example, at 90VAC main input under full load, the PFC controller will function as a quasi-CRM controller at the peak of the AC line cycle, as shown in Figure 13. Figure 13. DCM and quasi-CRM Operation with CS1501 The zero-current detection (ZCD) of the boost inductor is achieved using an auxiliary winding. When the stored energy of the inductor is fully released to the output, the voltage on the ZCD pin decreases, triggering a new switching cycle. This quasi-resonant switching allows the active switch to be turned on with near-zero inductor current, resulting in a nearly lossless switch event. This minimizes turn-on losses and EMI noise created by the switching cycle. Power factor correction control is achieved during light load by using on-time modulation. 5.2 Startup vs. Normal Operation Mode The CS1501 has two discrete operation modes: startup and normal. Startup mode will be activated when Vlink is less than 90% of nominal value, VO(startup) and remains active until Vlink reaches 100% of nominal value, as shown in Figure 14. Startup mode is activated during initial system power-up. Any Vlink drop to less than VO(startup), such as a load change, can cause the system to enter startup mode until Vlink is brought back into regulation. Figure 14. Startup and Normal Modes Startup mode is defined as a surge of current delivering maximum power to the output regardless of the load. During every active switch cycle, the 'ON' time is calculated to drive a constant peak current over the entire line cycle. However, the 'OFF' time is calculated based on the DCM/CCM boundary equation. 0 20 40 60 80 100 120 045 90 135 180 Rectified Line Voltage Phase (Deg.) Switching Freq. (% of Max.) Line Voltage (% of Max.) % PO max Vin < 181 VAC 20 70 50 60 40 40 5 20 0 60 80 100 Vin > 147 VAC 46 56 DCM Quasi CRM DCM Quasi CRM DCM ILB t [ms] IAC t[ms] Vlink [V] 100% 90% Normal Mode Normal Mode |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |