8 / 28 page ![]() 5 50-605 Kotron RF Point Model 80/81 Level Switches 2.5.2 Integral Mount with Flexible Probe Caution: Flexible probes are shipped with the cable clamp and the probe nut hand tightened. The end of a flexible probe MUST be secured to the bottom of the tank by either attachment to a bracket or to a heavy weight in order to keep the probe taut. 1. Unscrew probe from probe housing. Remove Mylar® hous- ing insulator located over the clamp. Refer to Figure 7. Caution: Do not discard Mylar housing insulator. 2. Attach weight (if used) to probe end. 3. Insert probe end through tank mounting bushing and feed cable into the tank. Do not allow probe insulation to be damaged by scraping against the bushing threads. Caution: Probe cable must not be in contact with anything metallic in its final installation position. 4. Secure lower end of probe (or optional weight) to tank bracket if one is used. Refer to Figure 7. 5. Apply thread sealant to mounting nut. 6. Screw mounting nut into tank bushing until tight. Caution: Apply wrench to lower probe nut only. NOTE: Do not allow the probe to fall in the tank while following steps 7 through 11. 7. Loosen both socket clamp screws. 8. Pull clamp and Teflon® retaining bushing off probe. 9. While holding probe cable, loosen upper probe nut. 10. Pull excess cable up through probe nuts until cable is taut. 11. Tighten the probe nuts. 12. Cut off cable 1.35 inches (34 mm) above top of upper probe nut and strip off 1.25 inches (32 mm) of insulation. 13. Slide Teflon retaining bushing onto cable and seat it into the upper probe nut. 14. Slide clamp onto cable and seat it in the Teflon retaining bushing. 15. Tighten both socket head clamp screws to approximately 35 in./lbs. torque. 16. Slip Mylar housing insulator over clamp. 17. Screw housing onto probe and tighten. Make sure conduit connection is properly aligned for wire entry. Caution: Check probe terminal connection carefully to be certain lug will not short to packing gland or interfere with assem- bly of amplifier housing to probe. 18. Proceed to Section 2.7, Wiring on page 8. Probe Connection Screw Socket Head Clamp Screws (2) Upper Probe Mounting Gland Lower Probe Mounting Gland Mylar Housing Insulator (slips over clamp) Teflon Retaining Bushing Clamp Optional Weight Tank Bracket Connection Optional Mounting Bracket (Used w/ Insulated Probes) Probe Locking Set Screw Flexible Probe Probe Termination Figure 7 Flexible Probe Assembly |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |