9 / 20 page ![]() LTC2995 9 2995f OPERATION Overview The LTC2995 combines the functionality of a temperature measurement and monitor device with a dual voltage supervisor. It provides a buffered voltage proportional to the absolute temperature of either an internal or a remote diode (VPTAT) and compares this voltage to thresholds that can be set by external resistor dividers from the on-board reference (VREF). The LTC2995 also provides four voltage threshold inputs that are continuously compared to an internal 0.5V reference allowing two systems voltages to be monitored for undervoltage and overvoltage conditions. Diode Temperature Sensor Temperature measurements are conducted by measuring the voltage of either an internal or an external diode with multiple test currents. The relationship between diode voltage VD and diode current ID can be solved for absolute Temperature in degrees Kelvin T: ⎛ ⎝⎜ ⎞ ⎠⎟ T = q η k VD ln ID IS where IS is a process dependent factor on the order of 10–13A, η is the diode ideality factor, k is the Boltzmann constant and q is the electron charge. This equation shows a relationship between temperature and voltage dependent on the process depended variable IS. Measuring the same diode (with the same value IS) at two different currents (ID1 and ID2) yields an expression independent of IS: ln ID2 ID1 ⎛ ⎝⎜ ⎞ ⎠⎟ T = q η k VD2 –VD1 Series Resistance Cancellation Resistance in series with the remote diode causes a positive temperature error by increasing the measured voltage at each test current. The composite voltage equals: ⎛ ⎝⎜ ⎞ ⎠⎟ VD + VERROR =η kT q ln ID IS + RS ID The LTC2995 removes this error term from the sensor signal by subtracting a cancellation voltage VCANCEL. A resistance extraction circuit uses one additional current measurement to determine the series resistance in the measurement path. Once the correct value of the resistor is determined, VCANCEL equals VERROR. Now the temperature to voltage converter input signal is free from errors due to series resistance. LTC2995 can cancel series resistances up several hundred ohms (see Typical Performance Characteristics curves). Higher series resistances cause the cancelation voltage to saturate. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |