49 / 56 page ![]() Sensor Freescale Semiconductor, Inc. 49 MMA65xx 4.4 Register Access Operations Two types of register access operations are supported; register write, and register read. Register access operations are initi- ated when the acceleration bit (A) of the command message is set to a logic ‘0’. The operation to be performed is indicated by the Access Selection bit (AX) of the command message. Register Access operations include a parity bit (P). Odd parity is employed. The number of logic ‘1’ bits in the Register Access operation must be an odd number. 4.4.1 Register Write Request During a register write request, bits 12 through 8 contain a five-bit address, and bits 7 through 0 contain the data value to be written. Writable registers are defined in Table 3. The response to a register write operation is shown in Table 30. The response is transmitted on the next SPI message if and only if all of the following conditions are met: • No SPI Error is detected (Reference Section 4.5.1) • No MISO Error is detected (Reference Section 4.5.2) • The ENDINIT bit is cleared (Reference Section 3.1.6.3) – This applies to all registers with the exception of the DEVCTL register (Only Bits 6 and 7 can be modified) • No Invalid Register Request is detected (Reference Section 4.5.3.2) If the above conditions are met, the device responds to the register write request as shown in Table 30. Otherwise, the device Responds as specified in Section 4.5. Register write operations do not occur internally until the transfer during which they are requested has been completed. In the event that a SPI Error is detected during a register write transfer, the write operation is not completed. 4.4.2 Register Read Request During a register read request, bits 12 through 8 contain the five-bit address for the register to be read. Bits 7 through 0 must be logic ‘0’. Readable registers are defined in Table 3. The response to a register read operation is shown in Table 30. The response is transmitted on the next SPI message if and only if all of the following conditions are met: • No SPI Error is detected (Reference Section 4.5.1) • No MISO Error is detected (Reference Section 4.5.2) • No Invalid Register Request is detected (Reference Section 4.5.3.2) If the above conditions are met, the device responds to the register read request as shown in Table 30. Otherwise, the device responds as specified in Section 4.5. Access Selection Bit (AX) Operation 0 Register Read 1 Register Write |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |