| 数据搜索系统,热门电子元器件搜索 |
|
SS22SDP2 数据表(PDF) 18 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
SS22SDP2 数据表(HTML) 18 Page - Texas Instruments |
|
18 / 31 page ![]() Serial Console www.ti.com Recording time is not measured, but calculated from the number of samples collected. The speed is used to determine the amount of time for each sample. If the data rate is changed at the board, the recording time will be incorrect. This change does not affect the data file, except that samples continue to be collected with the different settings. In Recording mode, analysis proceeds as in Analysis mode; Recording mode is identical to Analysis mode, except that data is written to a file. See the previous section for documentation on Analysis mode. When Recording mode begins, if the selected file exists, it is erased and overwritten. The pre-existence of the file is checked only when a new file is selected. 4.7.1 File Format Data files begin with a header that contains the text collected from ADS1x31REF, the time of recording, and the speed and gain. Following this header, values are written in either volts or raw codes, with one value per line. Line separators are in DOS format, consisting of a carriage return and a line feed. This format can be examined in a text editor and loaded or imported into most other software, including spreadsheets. Voltages are calculated using the reference voltage given in the Vref control; it is therefore important that this value be correct. 5 Serial Console The ADS1x31REF provides a console mode that can be used with any Windows terminal emulation program, such as Hyperterm ™. In Windows, this configuration is done through the Virtual COM Port driver supplied with the EVM software, causing the ADS1x31REF to appear in Windows as an extra serial port. 5.1 Using the Console To use the console, load a terminal emulation program and connect to the EVM serial port using the following parameters: • Baud rate: 115200 • Data bits: 8 • Parity: none • Stop bits: 1 • Flow control: none • Local echo: off • Terminal emulation: ANSI or VT100 Setting up the terminal program is beyond the scope of this document; see the specific terminal program documentation for details. To locate the serial port, try higher port numbers first. When the board first starts, it outputs the following message: ADS1131REF 1.0.0 (c)2010 Texas Instruments 1131> for the ADS1131, or : ADS1231REF 1.0.0 (c)2010 Texas Instruments 1231> for the ADS1231. Pressing Reset causes the board to output this message. The command prompt is always 1131> for the ADS1131 and 1231> for the ADS1231. Commands are entered at this prompt. Commands consist of one letter possibly followed by arguments. The format of the arguments depends on the command. Commands are case insensitive. Upper-case characters are printed here, but lower-case characters also work. 18 ADS1131REF and ADS1231REF SBAU175A – July 2010 – Revised August 2011 Submit Documentation Feedback Copyright © 2010–2011, Texas Instruments Incorporated |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |