13 / 39 page ![]() STCD22x0, STCD23x0, STCD24x0 Device operation Doc ID 15400 Rev 2 13/39 Note: "0" means logic low and "1" means logic high. When there is NO CLOCK output, the CLKx pin stays at logic low. "X" means don't care. This is an active high truth table. Refer to Section 3.2: Enable polarity for the detailed enable active high/low options. 3.2 Enable polarity In different applications, the user may have different requirements for enable active high or active low (enable polarities). MCREQ is active low. STMicroelectronics offers different solutions for the user to obtain different enable polarities. In the STCD22x0 and STCD24x0, the user can configure the enable active high or active low on the PC board by connecting OPT1 and OPT2 to either VCC or ground. Refer to Table 7 for detailed information. In the STCD23x0, STMicroelectronics offers 4 enable polarity options by factory programming for the user. Refer to Table 7 for detailed information. The user should note that OPT1 and OPT2 must be connected to either VCC or GND on the PC board and floating on these pins could cause problems. Table 6. Truth table for enable signals (EN1-4), master clock input (MCLK) and output clocks (CLK1-4) EN1 EN2 EN3 EN4 MCLK CLK1 CLK2 CLK3 CLK4 0 0 0 0 X NO CLOCK NO CLOCK NO CLOCK NO CLOCK 1 0 0 0 CLOCK CLOCK NO CLOCK NO CLOCK NO CLOCK 1 1 0 0 CLOCK CLOCK CLOCK NO CLOCK NO CLOCK - - - - - ---- 1 1 1 1 CLOCK CLOCK CLOCK CLOCK CLOCK Table 7. STCD22x0, STCD23x0 and STCD24x0 and enable polarity options Part number Enable polarities (OPT1, OPT2) Enable polarity program method STCD2200 OPT1 connected to VCC, EN1 active high OPT1 connected to GND, EN1 active low OPT2 controls EN2 User program STCD2400 OPT1 connected to VCC, EN1 and EN2 active high OPT1 connected to GND, EN1 and EN2 active low OPT2 controls EN3 and EN4 STCD2410 OPT1 connected to VCC, EN1 active high OPT1 connected to GND, EN1 active low OPT2 controls EN2, EN3, and EN4 STCD2300 EN1, EN2 and EN3 all active low Factory program STCD2310 EN1, EN2 active low, and EN3 active high STCD2320 EN1, EN2 active high and EN3 active low STCD2330 EN1, EN2 and EN3 all active high |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |