Back Button EMPROT Datasheet HTML 4Page - rfsolutions.ltd EMPROT Datasheet HTML 5Page - rfsolutions.ltd EMPROT Datasheet HTML 6Page - rfsolutions.ltd EMPROT Datasheet HTML 7Page - rfsolutions.ltd EMPROT Datasheet HTML 8Page - rfsolutions.ltd EMPROT Datasheet HTML 9Page - rfsolutions.ltd EMPROT Datasheet HTML 10Page - rfsolutions.ltd EMPROT Datasheet HTML 11Page - rfsolutions.ltd EMPROT Datasheet HTML 12Page - rfsolutions.ltd Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 17 page
background image
ib technology
8
Host Driver software
Communication with the MicroRWD module is via the TTL level RS232 interface (9600
baud, 8 bit, 1 stop bit, no parity) and uses the CTS line for hardware handshaking. The
Windows applications (supplied with the Evaluation kit) can be used to communicate with the
module or the user can write their own application on a PC or a microcontroller. Please note
that the host software must be able to handle the three distinct polling rates (different periods
between CTS pulses). The following basic communication algorithm can be used:-
Typical host computer “pseudo” driver code
if (Green LED ON (pin 2 = 0))
// Optional check for valid tag in field
{
if (CTS = 0)
// Wait for CTS = 0 (RWD ready to receive command / data)
{
// CTS times out after 6ms so command and all parameters must be sent with
// no gaps otherwise CTS times out and goes HIGH.
// For example, send READ TAG command (with dummy page no.) (0x52 0x00)
SEND_BYTE( 0x52);
// Send command
SEND_BYTE( 0x00);
// Send argument 1
// RWD sets CTS = 1 after last parameter received. RWD module processes
// command, turns on RF for short period, waits then sends reply.
GET_REPLY( );
// Get Acknowledge byte + data
// Response to READ command is 0xC0 (no tag) or 0xD6 + five bytes of DATA.
}
}
Command Protocol
The following commands are supported. The corresponding acknowledge code should be read
back by the host and decoded to confirm that the command was received and actioned
correctly. The serial bit protocol is 9600 baud, 8 bits, 1 stop, no parity (lsb transmitted first).
The status flags returned in the Acknowledge byte are as follows:
b7 b6 b5 b4 b3 b2 b1 b0
1
1
1
1
1 1 1 1
|
|
|
|
|
EEPROM error (Internal EEPROM write error)
|
|
|
| Tag OK (Tag identity code matched to list and authentication successful)
|
|
| Rx OK (Tag communications and acknowledgement OK)
|
|
RS232 error (Host serial communications error)
|
RELAY (OP2, OP3) Enabled flag
HTRC (or Antenna fault) error flag
Note that bits 6 and 7 are fixed 1’s so that an acknowledge code of D6 (Hex) would generally indicate no errors
with a matched (or authorised) Tag present.
Note also that only the relevant flags are set after each command as indicated in the following specification.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com