| 数据搜索系统,热门电子元器件搜索 |
|
MFPROT_LP 数据表(PDF) 5 Page - rfsolutions.ltd |
|
|
|||||||||||||||||||||||||||||
MFPROT_LP 数据表(HTML) 5 Page - rfsolutions.ltd |
|
5 / 35 page ![]() ib technology 5 The CTS line remains in a LOW state while the command and data bytes are being received. After the last byte of data the CTS signal “times out” for 6ms and returns HIGH. This 6ms “window” every polling cycle allows the host computer to send a single command and associated data to the RWD. Please note that only one command and it’s corresponding data bytes can be sent during a CTS LOW period, the command and data bytes must be sent with no gaps between, if there is a pause of more than 6ms between bytes then “time out” occurs, the CTS line returns high and the command fails (flagged as RS232 error). The CTS signal idles in this HIGH state (to inhibit host communication) until the next polling cycle begins. The communication baud rate is 9600 baud, 8 bits, 1 stop, no parity. The RWD Tx, Rx and CTS signals are all TTL level and can be converted to +/-10v RS232 levels using a level converter device such as the MAX202 (note the inversion of the TTL levels). The Micro RWD MF LP (low-power) version has been specifically designed to operate with very low average power consumption but still remain responsive to cards entering and leaving the field and be able to read large amounts of data as quickly as possible. THE RWD HAS THREE POLLING STATES: 1) NO card present and NO host commands received. Polling cycle rate (time between subsequent CTS low periods) is determined by the “polling rate” parameter stored in the RWD EEPROM memory. This is typically set to a long period (4ms to 8 seconds, default setting 260mS) and is the primary means to reduce average power consumption. This is because most of the polling cycle period is spent in a power-down/sleep mode. 2) Mifare card in field, NO host commands received. When a card is detected in the field the polling rate changes to approximately 100ms (between CTS low periods). This is to ensure that the RWD can respond quickly to the card leaving the field and a new card being presented. 5v 0v Polling cycle repeats CTS TTL levels Polling cycle period set by RWD EEPROM parameter (4ms to 8 seconds, default 1 second) 6ms (CTS timeout) RF OFF, Power-down/sleep period RF ON for brief period (to check for card) 5v 0v Polling cycle repeats CTS TTL levels 100ms polling rate 6ms (CTS timeout) RF OFF, Power-down/sleep period RF ON for brief period (to check for card) 100ms polling rate Not to scale Not to scale |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |