| 数据搜索系统,热门电子元器件搜索 |
|
ACT8828 数据表(PDF) 48 Page - Active-Semi, Inc |
|
|
|||||||||||||||||||||||||||||
ACT8828 数据表(HTML) 48 Page - Active-Semi, Inc |
|
48 / 50 page ![]() ActivePath TM CHARGER ACT8828 Rev 7, 15-Nov-12 Innovative Power TM - 48 - www.active-semi.com Copyright © 2012 Active-Semi, Inc. ActivePMU TM and ActivePathTM are trademarks of Active-Semi. I 2CTM is a trademark of NXP. FUNCTIONAL DESCRIPTION CONT’D battery chargers. When the voltage at CHG_IN falls below VBAT, the charger automatically reconfigures its power switch to minimize current drain from the battery Charger State-Machine PRECONDITION State A new charging cycle begins with the PRECONDITION state, and operation continues in this state until VBAT exceeds the Precondition Threshold Voltage of 2.87V (typ). When operating in PRECONDITION state, the cell is charged at a reduced current, 12% of the programmed maximum fast-charge constant current, ISET. Once VBAT reaches the Precondition Threshold Voltage the state machine jumps to the FAST-CHARGE state. If VBAT does not reach the Precondition Threshold Voltage before the Precondition Timeout period tPRECONDITION expires, then a damaged cell is detected and the state machine jumps to the TIMEOUT-FAULT State. For the Precondition Timeout period, see the Charging Safety Timers section for more information. FAST-CHARGE State In FAST-CHARGE state, the ACT8810 charges at the current programmed by RISET (see the Current Limits and Charge Current Programming section for more information). During a normal charge cycle fast-charge continues in CC mode until VBAT reaches the charge termination voltage (VTERM), at which point the ACT8810 jumps to the TOP-OFF state. If VBAT does not reach VTERM before the total time out period expires then state-machine will jump to the END-OF-CHARGE (EOC) state and will re- initiate a new charge cycle after 2-4ms “relax”. TOP-OFF State In the TOP-OFF state, the cell charges in constant voltage (CV) mode. In CV mode operation, the charger regulates its output voltage to the 4.20V (typ) charge termination voltage, and the charge current is naturally reduced as the cell approaches full charge. Charging continues until the charge current drops to END-OF-CHARGE current threshold, at which point the state machine jumps to the END-OF-CHARGE (EOC) state. If the state- machine does not jump out of the TOP-OFF state before the Total-Charge Timeout period expires, the state machine jumps to the EOC state and will re- initiate a new charge cycle if VBAT falls below termination voltage 170mv (typ). For more information about the charge safety timers, see the Charging Safety Times section. END-OF-CHARGE State In the End-of-Charge (EOC) state, the ACT8810 presents a high-impedance to the battery, allowing the cell to “relax” and minimizes battery leakage current. The ACT8810 continues to monitor the cell voltage, so that it can re-initiate charging cycles when VBAT drops to 170mV (typ) below the Charge Termination Voltage. SUSPEND State The ACT8828 features an user-selectable suspend- charge mode, which disables the charger but keeps other circuiting functional. The charger can be put into suspend mode by driving EN to logic low. Upon exiting the SUSPEND State, the charge timer is reset and the state machine jumps to PRECONDITION state. CHG_IN Bypass Capacitor Selection CHG_IN is the power input for the ACT8828 battery charger. The battery charger is automatically enabled whenever a valid voltage is present on CHG_IN. In most applications, CHG_IN is connected to either a wall adapter or USB port. Under normal operation, the input of the charger will often be “hot-plugged” directly to a powered USB or wall adapter cable, and supply voltage ringing and overshoot may appear at the CHG_IN pin. In most applications a high quality capacitor connected from CHG_IN to GA, placed as close as possible to the IC, is sufficient to absorb the energy. Wall-adapter powered applications provide flexibility in input capacitor selection, but the USB specification presents limitations to input capacitance selection. In order to meet both the USB 2.0 and USB OTG (On The Go) specifications while avoiding USB supply under-voltage conditions resulting from the current limit slew rate (100mA/µS) limitations of the USB bus, the CHG_IN bypass capacitance value must to be between 4.7µF and 10µF for the ACT8828. Ceramic capacitors are often preferred for bypassing applications due to their small size and good surge current ratings, but care must be taken |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |