13 / 17 page ![]() 13 DATA SHEET - Rev 2.1 11/2012 ARA2017 Table 6: programming Register loGic pRoGRAMMinG figure 18: Serial Data input Timing programming instructions The programming word is set through a 10 bit shift register via the data, clock and enable lines. The data is entered in order with the most significant bit (MSB) first and the least significant bit (LSB) last. The enable line must be low for the duration of the data entry, then set high to latch the shift register. The rising edge of the clock pulse shifts each data value into the register. Notes: (1) Refer to Application Information section for Current and Gain bit settings. (2) Data bit 0 should always be set to “1”. (3) Data bit 1 is reserved for future use, and should be set to “0”. DATA BiT 9 8 7 6 5 4 3 2 1 0 funcTion Current Gain 0 1 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|