| 数据搜索系统,热门电子元器件搜索 |
|
MPL115A2 数据表(PDF) 4 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPL115A2 数据表(HTML) 4 Page - Freescale Semiconductor, Inc |
|
4 / 16 page ![]() Sensors 4 Freescale Semiconductor, Inc. MPL115A2 3 Overview of Functions/Operation Figure 2. Sequence Flow Chart The MPL115A interfaces to a host (or system) microcontroller in the user’s application. All communications are via I2C. A typical usage sequence is as follows: Initial Power-up All circuit elements are active. I2C port pins are high impedance and associated registers are cleared. The device then enters standby mode. Reading Coefficient Data The user then typically accesses the part and reads the coefficient data. The main circuits within the slave device are disabled during read activity. The coefficients are usually stored in the host microcontoller local memory but can be re-read at any time. It is not necessary to read the values stored in the host microcontroller multiple times because the coefficients within a device are constant and do not change. However, note that the coefficients will be different from device to device, and cannot be used for another part. Data Conversion This is the first step that is performed each time a new pressure reading is required which is initiated by the host sending the CONVERT command. The main system circuits are activated (wake) in response to the command and after the conversion completes, the result is placed into the Pressure and Temperature ADC output registers. The conversion completes within the maximum conversion time, tc (see Row 7, in the Operating Characteristics Table). The device then enters standby mode. Compensated Pressure Reading After the conversion has been given sufficient time to complete, the host microcontroller reads the result from the ADC output registers and calculates the Compensated Pressure, a barometric/atmospheric pressure value which is compensated for changes in temperature and pressure sensor linearity. This is done using the coefficient data from the MPL115A and the raw sampled pressure and temperature ADC output values, in a compensation equation (detailed later). Note that this is an absolute pressure measurement with a vacuum as a reference. From this step the host controller may either wait and then return to the Data Conversion step to obtain the next pressure reading or it may go to the Shutdown step. Reading coefficient data Data conversion Initial powerup Compensated pressure reading Shutdown |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |