21 / 56 page ![]() ADM1026 Rev. A | Page 21 of 56 C1* D+ D– REMOTE SENSING TRANSISTOR IN × I IBIAS VDD VOUT+ TO ADC VOUT– BIAS DIODE LOW-PASS FILTER fC = 65kHz CAPACITOR C1 IS OPTIONAL. IT IS ONLY NECESSARY IN NOISY ENVIRONMENTS. C1 = 2.2nF TYPICAL, 3nF MAX. * Figure 34. Signal Conditioning for Remote Diode Temperature Sensors The results of external temperature measurements are stored in 8-bit, twos complement format, as illustrated in Table 7. Table 7. Temperature Data Format Temperature Digital Output Hex −128°C 1000 0000 80 −125°C 1000 0011 83 −100°C 1001 1100 9C −75°C 1011 0101 B5 −50°C 1100 1110 CE −25°C 1110 0111 E7 −10°C 11110110 F6 0°C 0000 0000 00 10°C 0000 1010 0A 25°C 0001 1001 19 50°C 0011 0010 32 75°C 0100 1011 4B 100°C 0110 0100 64 125°C 0111 1101 7D 127°C 0111 1111 7F Layout Considerations Digital boards can be electrically noisy environments. Take these precautions to protect the analog inputs from noise, particularly when measuring the very small voltages from a remote diode sensor. • Place the ADM1026 as close as possible to the remote sensing diode. Provided that the worst noise sources such as clock generators, data/address buses, and CRTs are avoided, this distance can be 4 to 8 inches. • Route the D+ and D− tracks close together, in parallel, with grounded guard tracks on each side. Provide a ground plane under the tracks if possible. • Use wide tracks to minimize inductance and reduce noise pickup. A 10 mil track minimum width and spacing is recommended. 10MIL 10MIL 10MIL 10MIL 10MIL 10MIL 10MIL GND D+ GND D– Figure 35. Arrangement of Signal Tracks • Try to minimize the number of copper/solder joints, which can cause thermocouple effects. Where copper/solder joints are used, make sure that they are in both the D+ and D− paths and are at the same temperature. • Thermocouple effects should not be a major problem because 1°C corresponds to about 240 µV, and thermocouple voltages are about 3 µV/°C of temperature difference. Unless there are two thermocouples with a big temperature differential between them, thermocouple voltages should be much less than 200 mV. • Place a 0.1 µF bypass capacitor close to the ADM1026. • If the distance to the remote sensor is more than eight inches, the use of twisted-pair cable is recommended. This works from about 6 to 12 feet. • For very long distances (up to 100 feet), use shielded twisted pair such as Belden #8451 microphone cable. Connect the twisted pair to D+ and D− and the shield to GND close to the ADM1026. Leave the remote end of the shield unconnected to avoid ground loops. Because the measurement technique uses switched current sources, excessive cable and/or filter capacitance can affect the measurement. When using long cables, the filter capacitor may be reduced or removed. Cable resistance can also introduce errors. A 1 Ω series resistance introduces about 0.5°C error. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |