21 / 48 page ![]() REV. 0 ADM1029 –21– FAN-RELATED REGISTERS Table IX is a list of registers on the ADM1029 that are specific to fan speed measurement and control: Table IX. Fan-Specific Registers Address Description 0x02 Fans Supported By Controller 0x03 Fans Supported In System 0x07 Set Fan x Alarm Speed 0x08 Set Fan x Hot-Plug Speed 0x09 Set Fan x Full Speed 0x10 Fan 1 Status 0x11 Fan 2 Status 0x18 Fan 1 Fault Action 0x19 Fan 2 Fault Action 0x20 Fan 1 Event Mask 0x21 Fan 2 Event Mask 0x48 Local Temp Cooling Action 0x49 Remote 1 Cooling Action 0x4A Remote 2 Cooling Action 0x60 Fan 1 Minimum/Alarm Speed 0x61 Fan 2 Minimum/Alarm Speed 0x68 Fan 1 Configuration 0x69 Fan 2 Configuration 0x70 Fan 1 Tach Value 0x71 Fan 2 Tach Value 0x78 Fan 1 Tach High Limit 0x79 Fan 2 Tach High Limit FAN CONFIGURATION REGISTERS Registers 0x68 and 0x69 are the Fan 1 and Fan 2 Configuration Registers. These allow the PWM output frequencies to be selected for each fan. The default PWM drive frequency is 250 Hz. Bits <7:6> adjust the fan tach oscillator frequency for fan tach mea- surements. Bits <3:0> allow the Hot Plug PWM duty cycle value for each fan to be programmed. Figures 16 and 17 show how to configure the fans to handle thermal or fault events. Table VIII. Resistor Ratios for Setting TMIN and Number of Fans Installed Using TMIN/INSTALL Pin (Pin 18) 3 MSBs Ideal Ratio R1 R2 Actual Error Fans of ADC R2/(R1 + R2) (k )(k ) R2/(R1 + R2) (%) TMIN Installed 111 N/A 0 1 0 Disabled 2 110 0.8125 18 82 0.82 0.75 48 °C2 101 0.6875 22 47 0.6812 –0.63 40 °C2 100 0.5625 12 15 0.5556 –0.69 32 °C2 011 0.4375 15 12 0.4444 0.69 32 °C1 010 0.3125 47 22 0.3188 0.63 40 °C1 001 0.1875 82 18 0.18 –0.75 48 °C1 000 N/A 0 0 0 Disabled 1 In this case, since the Minimum Duty Cycle is the default 33%, the equation for TMAX reduces to: TMAX = TMIN + ((Max DC – Min DC) × T RANGE/10) TMAX = TMIN + ((15 – 5) × TRANGE/10) TMAX = TMIN + (10 × TRANGE/10) TMAX = TMIN + TRANGE ENABLING AUTOMATIC FAN SPEED CONTROL USING TMIN/INSTALL PIN (PIN 18) Automatic fan control can also be enabled in hardware by Pin 18 (TMIN/INSTALL). This is an 8-level input with multiple functions, which is sampled only at power-up. If only one fan is installed, the voltage on Pin 18 should be kept at less than VCC/2, which clears Bit 1 of register 03h. Within this voltage range, four voltage levels define the minimum temperature at which the fan will operate in automatic speed control mode. If two fans are installed, the voltage on Pin 18 should be between VCC/2 and VCC, which sets Bit 1 of register 03h. Within this voltage range, four voltage levels define the minimum temperature at which the fans will operate in automatic speed control mode. Resistor values for setting the voltage on Pin 18 are given in Table VIII. If automatic fan speed control is not used, Pin 18 can simply be strapped to ground (one fan) or VCC (two fans), depending on how many fans are installed. Under this condi- tion, the fans will run full speed until the device is written to by software to change fan speed. When automatic fan speed control is enabled at power-up by the TMIN/INSTALL pin, Bit 4 of the Configuration register is set to enable monitoring, and Bits 0 and 1 of all Temp. Cooling Action Registers are set, so any temperature channel will auto- matically control all fans that are installed. Note: if automatic fan speed control is enabled and an event occurs that would cause a fan to go to alarm or hot-plug speed (e.g., temperature fault), that event will override the automatic fan speed control. If the event affects only one fan, the other fan will remain under automatic control. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |