65 / 222 page ![]() 2013 Microchip Technology Inc. DS22331A-page 65 MCP19111 10.0 RELATIVE EFFICIENCY MEASUREMENT With a constant input voltage, output voltage and load current, any change in the high-side MOSFET on-time represents a change in the system efficiency. The MCP19111 is capable of measuring the on-time of the high-side MOSFET. Therefore, the relative efficiency of the system can be measured and optimized by changing the system parameters, such as switching frequency, driver dead time or high-side drive strength. 10.1 Relative Efficiency Measurement Procedure To measure the relative efficiency, the RELEFF regis- ter, ABECON<MEASEN> and ABECON<RECIREN> bits, and the ADC RELEFF input are used. The following steps outlines the measurement process: 1. Set the ABECON<RECIREN> bit to enable the measurement circuitry. 2. Clear the ABECON<MEASEN> bit. 3. With the ADC, read the RELEFF channel and store this reading as the High. 4. With the ADC, read the VZC channel and store this reading as the Low. 5. Set the ABECON<MEASEN> bit to initiate a measurement cycle. 6. Monitor the RELEFF<MSDONE> bit. When set, it indicates the measurement is complete. 7. When the measurement is complete, use the ADC to read the RELEFF channel. This value becomes the Fractional variable in Equation 10 1. This reading should be accomplished approximately 50ms after the RELESS<MSDONE> bit is set. 8. Read the value of the RE<6:0> bits in the RELEFF register and store the reading as Whole. 9. Clear the ABECON<MEASEN> bit. 10. The relative efficiency is then calculated by the following equation: EQUATION 10-1: Note 1: The RELEFF<MSDONE> bit is set and cleared automatically. Whole Fractional Low – High Low – -------------------------------------------------- + PR2 1 + -------------------------------------------------------------------------------- Where: Whole = Value obtained in Step 8 of the measurement procedure Fractional = Value obtained in Step 7 of the measurement procedure High = Value obtained in Step 3 of the measurement procedure Low = Value obtained in Step 4 of the measurement procedure Duty_Cycle = REGISTER 10-1: RELEFF: RELATIVE EFFICIENCY MEASUREMENT REGISTER R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 MSDONE RE6 RE5 RE4 RE3 RE2 RE1 RE0 bit 7 bit 0 Legend: R = Readable bit P = Programmable bit U = Unimplemented bit, read as ‘0’ -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bit 7 MSDONE: Relative efficiency measurement done bit 1 = Relative efficiency measurement is complete 0 = Relative efficiency measurement is not complete bit 6-0 RE<6:0>: Whole clock counts for relative efficiency measurement result |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |