| 数据搜索系统,热门电子元器件搜索 |
|
CPC7581BA 数据表(PDF) 12 Page - IXYS Corporation |
|
|
|||||||||||||||||||||||||||||
CPC7581BA 数据表(HTML) 12 Page - IXYS Corporation |
|
12 / 15 page ![]() INTEGRATED CIRCUITS DIVISION 12 www.ixysic.com R06 CPC7581 state. At this point the current measured through the break switches (SW1 and SW2) will drop to zero. Once the device enters thermal shutdown it will remain in the all-off state until the temperature of the device drops below the de-activation level of the thermal shutdown circuit. This permits the device to return to normal operation. If the transient has not passed, current will flow at the value allowed by the dynamic DC current limiting of the switches and heating will begin again, reactivating the thermal shutdown mechanism. This cycle of entering and exiting the thermal shutdown mode will continue as long as the fault condition persists. If the magnitude of the fault condition is great enough, the external secondary protector could activate and shunt all current to ground. The TSD pin is a pull-up current source with a nominal value of 300 A biased from V DD. For applications using low-voltage logic devices (lower than VDD), IXYS Integrated Circuits Division recommends the use of an open-drain type output to control TSD. This avoids sinking the TSD bias current to ground during normal operation when the all-off state is not required. 2.5 Ringing Switch Zero-Cross Current Turn Off After the application of a logic input to turn SW4 off, the ringing switch is designed to delay the change in state until the next zero-crossing. Once on, the switch requires a zero-current cross to turn off, and therefore should not be used to switch a pure DC signal. The switch will remain in the on state no matter the logic input until the next zero crossing. These switching characteristics will reduce and possibly eliminate overall system impulse noise normally associated with ringing switches. See IXYS Integrated Circuits Division’s application note AN-144, Impulse Noise Benefits of Line Card Access Switches for more information. The attributes of ringing switch SW4 may make it possible to eliminate the need for a zero-cross switching scheme. A minimum impedance of 300 in series with the ring generator is recommended. 2.6 Power Supplies Both a +5 V supply and battery voltage are connected to the CPC7581. CPC7581 switch state control is powered exclusively by the +5 V supply. As a result, the CPC7581 exhibits extremely low power dissipation during both active and all-off states. The battery voltage is not used for switch control but rather as a supply for the integrated secondary protection circuitry. The integrated SCR is designed to trigger when pin 2 (TBAT) or pin 15 (RBAT) drops 2 to 4 V below the voltage on pin 16 (VBAT). This trigger prevents a fault-induced overvoltage event at the TBAT or RBAT nodes. 2.7 Battery Voltage Monitor The CPC7581 also uses the VBAT voltage to monitor battery voltage. If system battery voltage is lost, the CPC7581 immediately enters the all-off state. It remains in this state until the battery voltage is restored. The device also enters the all-off state if the system battery voltage goes more positive than –10 V, and remains in the all-off state until the battery voltage goes more negative than –15 V. This battery monitor feature draws a small current from the battery (less than 1 A typical) and adds slightly to the device’s overall power dissipation. Due to the nature of the internal protection circuitry, the VBAT pin can be biased via potentials applied to TBAT or RBAT. This allows the CPC7581 switches to operate, but offers no transient protection. The supply voltage applied to VBAT should therefor be the same supply voltage applied to the line driver device. 2.8 Protection 2.8.1 Diode Bridge/SCR The CPC7581 uses a combination of current limited break switches, a diode bridge/SCR clamping circuit, and a thermal shutdown mechanism to protect the SLIC device or other associated circuitry from damage during line transient events such as lightning. During a positive transient condition, the fault current is conducted through the diode bridge to ground via FGND. Voltage is clamped to a diode drop above ground. During a negative transient of 2 to 4 V more negative than the battery, the SCR conducts and faults are shunted to FGND via the SCR or the diode bridge. In order for the SCR to crowbar (or foldback), the on voltage (see “Protection Circuitry Electrical |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |