| 数据搜索系统,热门电子元器件搜索 |
|
MFU113 数据表(PDF) 2 Page - Minmax Technology Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
MFU113 数据表(HTML) 2 Page - Minmax Technology Co., Ltd. |
|
2 / 4 page ![]() MFU100 SERIES DC/DC CONVERTER 1W E-mail:sales@minmax.com.tw Tel:886-6-2923150 2012/01/09 REV:6 Page 2 of 4 Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Accuracy --- ±1.0 ±3.0 % Line Regulation For Vin Change of 1% --- ±1.2 ±1.5 % Load Regulation Io=20% to 100% See Model Selection Guide Ripple & Noise (20MHz) --- 100 150 mV P-P Ripple & Noise (20MHz) Over Line, Load & Temp. --- --- 200 mV P-P Ripple & Noise (20MHz) --- --- 15 mV rms Temperature Coefficient --- ±0.01 ±0.02 %/ ℃ Short Circuit Protection 0.5 Second Max. General Specifications Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage (rated) 60 Seconds 3000 --- --- VDC I/O Isolation Resistance 500 VDC 10 --- --- GΩ I/O Isolation Capacitance 100KHz, 1V --- 60 100 pF Switching Frequency 50 90 110 KHz MTBF (calculated) MIL-HDBK-217F@25 ℃, Ground Benign 2,000,000 --- --- Hours Input Fuse 5V Input Models 12V Input Models 24V Input Models 500mA Slow-Blow Type 200mA Slow-Blow Type 100mA Slow-Blow Type Environmental Specifications Parameter Conditions Min. Max. Unit Operating Temperature Range (with Derating) Ambient -40 +85 ℃ Case Temperature --- +90 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃ Power Derating Curve ~ ] Ambient Temperature 0 20 40 60 80 100 -40 0 20 60 100 110 80 40 400LFM 200LFM 100LFM Natural convection ~ ] Ambient Temperature 0 20 40 60 80 100 -40 0 20 60 100 110 80 40 400LFM 200LFM 100LFM Natural convection (5V Output Only) (All Other Output) Notes 1 Specifications typical at Ta=+25 ℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Ripple & Noise measurement bandwidth is 0-20MHz. 3 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 4 All DC/DC converters should be externally fused at the front end for protection. 5 Other input and output voltage may be available, please contact factory. 6 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 7 Specifications subject to change without notice. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |