| 数据搜索系统,热门电子元器件搜索 |
|
CT2579 数据表(PDF) 3 Page - Aeroflex Circuit Technology |
|
|
|||||||||||||||||||||||||||||
CT2579 数据表(HTML) 3 Page - Aeroflex Circuit Technology |
|
3 / 41 page ![]() 3 APPLICATION NOTE #108 Released 9/98 Signal Descriptions MIL-STD-1553 Bus Interface Signals Data0(Bus) Connect to positive side of the external databus transformer for Bus 0 Ndata0(Bus) Connect to negative side of the external databus transformer for Bus 0 Data1(Bus) Connect to positive side of the external databus transformer for Bus 1 Ndata1(Bus) Connect to negative side of the external databus transformer for Bus 1 Hard Wired Interface Signals AddrA-E Remote Terminal address inputs for the unit. ADDR A is the least significant bit and ADDR E is the most significant bit. RT Address inputs for the unit. AddrA is the LSB, AddrE is the MSB. AddrP Parity Bit for the RT Address inputs. AddrP must be set to ODD parity MACAIR This signal sets the unit to respond with a status word within 4 uS (dead bus time) while in Remote Terminal mode. Subaddress 1F is also enabled to be a valid subaddress for data. Normally subaddress 00 and 1F are reserved for mode codes. “1" = 4 uS dead bus response time, subaddress 1F used for data. “0" = 12 uS response time, subaddress 1F used for mode codes. NBIT16 Select 8 or 16 bit subsystem data interface. In 8 bit mode only the lower 8 bits of the databus (DATA 0-7) are used for all data transfers. If left open circuit the device will default to 16 bit mode. "0" = 16 Bit Mode "1" = 8 Bit Mode VME Select VME or MULTIBUS subsystem interface. If left open circuit the device will default to VME mode. "0" = Multibus Mode "1" = VME Mode *WRAPEN Select Remote Terminal wrap around to subaddress 1E. For this test to work correctly theunit must be in RT mode. The Bus Controller sends data to subaddress 1E which remains in the data buffer memory and is available to be sent back on the very next command by the Bus Controller. The data in the data buffer memory in this mode does not get transferred to the main RAM. If the very next command is not a transmit command to subaddress 1E, the data buffer memory is flushed and will respond normally to the next set of commands. If the wrap around test is enabled, data to subaddress 1E must be transferred in the correct sequence. "0" = Normal Mode "1" = Wrap Around Mode MIL-STD-1760 Signals NENCHK Enables / Disables the internal hardware checksum generation and validation for both Remote Terminal and Bus Controller. When enabled, the circuitry will check all |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |