2 / 28 page ![]() Operating time monitor error or contact operation count monitor error 2 3 OMRON's DRT2-series Smart Slaves do not just input and output ON/OFF signals. They collect a variety of value-added information to help increase the rate of operation without changing the wiring for existing DeviceNet networks. In particular, they allow the separation of control systems and maintenance systems so that maintenance systems can be created independently of control systems. PLC Configurator Control I/O DRT2-series Smart Slave Pneumatic valve (Connected device comment) Maintenance information Easy-to-view Display 2 3 Sensor (Connected device comment) Cylinder (Connected device comment) Control System Maintenance System Maintenance System Control System Operating time, contact operation counter Machine Operation Monitored by Slave Faster Maintenance Work 1 Use production site information in a variety of applications, such as maintenance and quality control. The Slave can hold comments, allowing quick identification of fault locations and faulty devices. The Slave Unit represents machine operating time and operational changes as data, enabling monitoring without increasing the load between controllers. By counting the number of ON/OFF operations and the total operating time, the Slave Unit can provide notification when maintenance is required. Measuring Counting Maintenance is required for cylinder 23A in inspection line A! All data can be converted to electronic format and, by combining with an OMRON PLC (CS/CJ Series), checked directly from Ethernet or the Internet to allow remote maintenance. Information monitoring for each Slave Collect a variety of data from maintenance systems without influencing control systems and productivity. Using OMRON Temperature Input Terminals for Maintenance Slave comment Status confirmation using the status icon Unit conduction time monitor error Communications power voltage monitor error If it takes too long to modify the ladder program on the Master when a Temperature Sensor is replaced: Slaves internally convert display values to temperature input values so the Controller program no longer has to be modified to perform this task. Short Startup If prolonging the time it takes to reach a certain temperature may degrade equipment: The operating time of a preset temperature range is counted in 1-s units. The peaks or valleys of temperature inputs that change in a regular pattern are counted to predict when devices operating with severe temperature swings are due for maintenance. Failure Prediction and Maintenance Sensor replaced by one with a different input range Operating time Indicator service life control Time Input Semiconductor manufacturing equipment Scaling performed inside the Slave Slaves can notify the Master when a setting is exceeded. Scaling points for 0% and 100% are set from the Configurator Maintenance System Maintenance System Control System Control System DRT2-series Smart Slave DeviceNet Configurator Ethernet Maintenance information PLC Control information Unit conduction time monitor (See note.) Operating time monitor External load short-circuit detection Contact operation counter (See note.) I/O power status monitor Communication error history monitor Network power voltage monitor Note: The contact operation counter function and the unit conduction time monitor function cannot be used simultaneously. Operating time monitor Contact operation counter Unit conduction time monitor Slave and connected component comments I/O power status monitor Reliable equipment startup Preventive maintenance of equipment Reduced startup time Reduced downtime It's time for motor maintenance! What is the present communications voltage? The cylinder's speed is incorrect! It might be time for a switch inspection! Is the I/O power supply turned ON? What was the cause of the error? Communication error history monitor Network power voltage monitor The wiring to the I/O device is short-circuited or broken! |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |