| 数据搜索系统,热门电子元器件搜索 |
|
PV37X503C01 数据表(PDF) 49 Page - Murata Manufacturing Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
PV37X503C01 数据表(HTML) 49 Page - Murata Manufacturing Co., Ltd. |
|
49 / 55 page ![]() SMD Sealed Type (PVG3/M4A_D01/G5)/Lead Sealed Type (PV32/12/37/36) Specifications and Test Methods Continued from the preceding page. Continued on the following page. 13 Low Temperature Operation (Only for PVM4A ---D01) The trimmer potentiometer should be placed in a chamber at a temperature of -25±3°C (-55±3°C for PVM4A ---D01 series) 48±4 hours without loading. The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for 1-2 hours. 12 Low Temperature Exposure (Except for PVM4A ---D01) The trimmer potentiometer should be placed in a chamber at a temperature of -55±3°C for 1 hours without loading. Full rated continuous working voltage not exceeding the maximum rated voltage should be applied for 45 minutes. The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for approximately 24 hours. 11 High Temperature Exposure The trimmer potentiometer should be placed in a chamber at a temperature of 125±3°C 250±8 hours without loading. The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for 1 to 2 hours. 10 Temperature Load Life Full rated continuous working voltage not exceeding the maximum rated voltage should be applied intermittently between terminal #1 and terminal #3 of the trimmer potentiometer, 1.5 hours on and 0.5 hours off, for a total of 1000±12 hours, at a temperature of 70±2°C (85±2°C for PV37 series). The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for 1 to 2 hours. 9 Shock 1) PV -- series The trimmer potentiometer should be shocked at the 100G level and should be subjected to 4 shocks in each of the three axis directions for a total of 12 shocks. 2) PVM4A ---D01 series The trimmer potentiometer should be shocked at the 100G level and should be subjected to 3 shocks in each of the six axis directions for a total of 18 shocks. 8 Vibration 1) PV -- series The trimmer potentiometer should be vibrated throughout the frequency range at the 20G level. A complete frequency range, 10Hz to 2000Hz and back, should be made within 15 minutes for a total of 4 sweeps in each of the three axis directions for a total of 12 sweeps. 7 Humidity 1) PV12, PV32, PVM4A ---D01 series The trimmer potentiometer should be placed in a chamber at a temperature of 40±2°C and a humidity of 90-95% without loading for 250±8 hours (500±12 hours for PVM4A ---D01 series). The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for 5±1/6 hours. 2) PVG3, PVG5, PV36, PV37 series The trimmer potentiometer should be subjected to the programmed humidity environment for 10 cycle (see Figure 3). The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for 1.5±1/2 hours. Figure 3 6 Temperature Cycle The trimmer potentiometer should be subjected to Table 4 temperature for 5 cycles. The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for 1-2 hours. Table 4: One cycle of temperature cycle. Sequence PV -- series 1 -55±3 30 2 +25±2 5 max. 3 +125±3 30 4 +25±2 5 max. Temp. (°C) Time (min.) No. Test Methods Item INITIAL CONDITIONING IN A DRY OVEN 24 HOURS INITIAL MEASUREMENTS AS SPECIFIED IN 3.2 CIRCULATION OF CONDITIONING AIR SHOULD BE AT A MINIMUM CUBIC RATE PER MINUTE EQUIVALENT TO 5 TIMES THE VOLUME OF THE CHAMBER 22 23 24 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 70 65 60 55 50 45 40 35 30 25 20 15 10 5 -5 -10 0 ONE CYCLE 24 HOURS. REPEAT AS SPECIFIED IN 3.3 PRIOR TO FIRST CYCLE UNLESS OTHERWISE SPECIFIED STEP 7 STEP 6 STEP 5 STEP 4 STEP 3 STEP 2 STEP 1 UNLESS OTHERWISE SPECIFIED TEMPERATURE TOLERANCE IS, ±2°C AT ALL POINTS WITHIN THE CHAMBER EXCEPT THE IMMEDIATE VICINITY OF THE SPECIMENS AND THE CHAMBER SURFACES STEP 7a STEPS 7a AND 7b PERFORMED DURING ANY 5 OF THE FIRST 9 CYCLES. HUMIDITY UNCONTROLLED DURING STEPS 7a AND 7b ONLY VOLTAGE APPLIED AS SPECIFIED IN 3.5 STEP 7b END OF FINAL CYCLE MEASUREMENTS AS SPECIFIED IN 3.6 +10°C -2°C HUMIDITY UNCONTROLLED RATE OF CHANGE OF TEMPERATURE IS UNSPECIFIED. HOWEVER, SPECIMENS SHOULD NOT BE SUBJECTED TO RADIANT HEAT FROM CHAMBER-CONDITIONING PROCESSES 90-98%RH 80-98%RH 90-98%RH 80-98%RH 90-98%RH MIL-STD-202 METHOD 106 R50E.pdf Jul.23,2012 47 !Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc. • This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |