47 / 55 page ![]() SMD Open Type (PVZ2/A2/Z3)/SMD Sealed Type (PVM4A_C01 Series) Specifications and Test Methods 9 Rotational Life The wiper should be rotated over 90% of the effective rotational angle without loading at a speed of 10 cycles per minute, for 10 cycles continuously. The resistance value should be measured after keeping the potentiometer in a room for 10±5 minutes. 8 Temperature Coefficient of Resistance The trimmer potentiometer should be subjected to each of the following temperatures (see Table 5, Table 6) for 30 to 40 minutes. The resistance value should be measured in the chamber. T1 : Reference temperature in degrees celsius T2 : Test temperature in degrees celsius R1 : Resistance at reference temperature in ohm R2 : Resistance at test temperature in ohm Table 5: PVZ Note*: Norm temp. Table 6: PVA2/PVM4A ---C01 7 Temperature Cycle The wiper contact point should be preset at about 50% position of effective rotational angle. After that, the potentiometer should be subjected to Table 3, Table 4 temperature for 5 cycles. The resistance value should be measured after keeping the potentiometer in a room for 1 to 2 hours. Table 3: PVZ Table 4: PVA2/PVM4A ---C01 6 Load Life The wiper contact point should be preset at about 50% position of effective rotational angle. After that, the potentiometer should be placed in a chamber at 70±2°C (50±2°C for PVZ) with loading the 1/2 rated voltage between #1 and #2 terminals, intermittently 1.5 hours ON and 0.5 hours OFF for 1000±12 hours. The resistance value should be measured after keeping the potentiometer in a room for 1 to 2 hours. 5 Humidity Load Life The wiper contact point should be preset at about 50% position of effective rotational angle. After that, the potentiometer should be placed in a chamber at 40±2°C and 90 - 95% with loading the 1/2 rated voltage between #1 and #2 terminals, intermittently 1.5 hours ON and 0.5 hours OFF for 1000±12 hours. The resistance value should be measured after keeping the potentiometer in a room for 5±1/6 hours. 4 High Temperature Exposure The wiper contact point should be preset at about 50% position of effective rotational angle. After that, the potentiometer should be placed in a chamber at 70±2°C without loading for 500±12 hours. The resistance value should be measured after keeping the potentiometer in a room for 1.5±1/6 hours. 3 Humidity Exposure The wiper contact point should be preset at about 50% position of effective rotational angle. After that, the potentiometer should be placed in a chamber at 40±2°C and 90 - 95% without loading for 500±12 hours. The resistance value should be measured after keeping the potentiometer in a room for 5±1/6 hours. 2 Contact Resistance Contact resistance variation should be measured with the measuring circuit shown below, or its equivalent. The operating wiper should be rotated in both directions through 90% of the actual effective-electrical travel for a total of 6 cycles. The rate of rotation of the operating wiper should be such that the wiper completes 1 count in determining whether or not a contact resistance variation is observed at least twice in the same location. The test current should follow the value given in Table 2 unless otherwise limited by the power rating. Table 2: Test current for CRV Figure 1: CRV measuring circuit 1 Residual Resistance Position the contact arm at the extreme counterclockwise limit of mechanical travel and measure the resistance between the contact arm and the corresponding end terminal. Then, position the contact arm at the extreme clockwise limit of mechanical travel and measure the resistance between the contact arm and the corresponding end terminal. During this test, take suitable precautions to ensure that the rated current of the resistance element is not exceeded. Standard Total Resistance R (ohm) Test Current 20mA max. 1mA max. 100μA max. 100 VR 10k VR 100k VR F10k F100k Sequence 1 -25±3 30±3 2 +25±2 10 max. 3 +85±3 30±3 4 +25±2 10 max. Temp. (°C) Time (min.) Sequence 1 -55±3 30±3 2 +25±2 10 max. 3 +125±3 30±3 4 +25±2 10 max. Temp. (°C) Time (min.) Sequence 1* +25±2 2 -25±3 3* +25±2 4 +85±3 Temp. (°C) Sequence 1* +25±2 2 -55±3 3* +25±2 4 +125±3 Temp. (°C) No. Test Methods Item The tests and measurements should be conducted under the conditions of 15 to 35°C of temperature, 25 to 75% of relative humidity and 86 to 106 kpa of atmospheric pressure unless otherwise specified. If questionable results occur that have been measured in accordance with the above-mentioned conditions, the tests and measurements should be conducted under the conditions of 25±2°C of temperature, 45 to 55% of relative humidity and 86 to 106 kpa of atmospheric pressure. Rx #1 #2 #3 Calibration resistance AC Amplifier vertical entry Oscilloscope Rx : Trimmer Potentiometer Oscilloscope bandwidth: 100Hz to 50kHz Constant Current Source (Test current shown in Table 2) TCR= R2 – R1 R1 (T2 – T1) Z 106 (ppm/°C) Standard Total Resistance R (ohm) Test Current 20mA 10mA 4mA 2mA 1mA R 100 FR 500 VR 1k VR 2k VR V100 F500 F1k F2k F50k Standard Total Resistance R (ohm) Test Current 200μA 100μA 50μA 30μA 50k VR 200k VR 1M VR 2M VR F200k F1M F2M · PVZ/PVA2 · PVM4A pppC01 R50E.pdf Jul.23,2012 45 !Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc. • This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |