| 数据搜索系统,热门电子元器件搜索 |
|
PVG5A503C03 数据表(PDF) 48 Page - Murata Manufacturing Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
PVG5A503C03 数据表(HTML) 48 Page - Murata Manufacturing Co., Ltd. |
|
48 / 55 page ![]() SMD Sealed Type (PVG3/M4A_D01/G5)/Lead Sealed Type (PV32/12/37/36) Specifications and Test Methods Continued on the following page. 5 Voltage Setting Stability The wiper should be set at approximately 40% of the actual effective-electrical rotational angle (number of turns). An adequate DC test potential should be applied between terminal #1 and terminal #3. The voltage between terminal #1 and terminal #3, and the voltage between terminal #1 and terminal #2, should be measured and applied to the following formula. Voltage setting stability= ( — E e' –— E e ) Z100 (%) e : Before test (The voltage between terminal #1 and terminal #2) e' : After test (The voltage between terminal #1 and terminal #2) Figure 2 4 Temperature Coefficient of Resistance The trimmer potentiometer should be subjected to each of the following temperatures (see Table 3) for 30-45 minutes. Temperature coefficient of resistance should be applied to the following formula. T1 : Reference temperature in degrees celsius T2 : Test temperature in degrees celsius R1 : Resistance at reference temperature in ohm R2 : Resistance at test temperature in ohm Note*: Reference temperature Table 3: Test temperatures 3 Contact Resistance Variation Contact resistance variation should be measured with the measuring circuit shown in Figure 1, or its equivalent. The adjustment rotor (screw) should be rotated in both directions through 90% of the actual effective-electrical rotational angle (number of turns) for a total of 6 cycles. Only the last 3 cycles should count in determining whether or not a contact resistance variation is observed at least twice in the same location, exclusive of the roll-on or roll-off points where the contact arm moves from the termination, on or off, the resistance element. The rate of rotation of the adjustment rotor (screw) should be such that the adjustment rotor (screw) completes 1 cycle for 5 seconds minimum to 2 minutes maximum. The test current used should follow the value given in Table 2 unless otherwise limited by power rating. Table 2: Test current for CRV Figure 1: CRV measuring circuit 2 Residual Resistance Position the contact arm at the extreme counterclockwise limit of mechanical travel and measure the resistance between the contact arm and the corresponding end terminal. Then, position the contact arm at the extreme clockwise limit of mechanical travel and measure the resistance between the contact arm and the corresponding end terminal. During this test, take suitable precautions to ensure that the rated current of the resistance element is not exceeded. 1 Total Resistance Measure total resistance between the resistance element and terminals (#1 and #3) with the contact arm positioned against a stop. The positioning of the contact arm and terminal should be the same for subsequent total resistance measurements on the same device. Use the test voltage specified in Table 1 for total resistance measurements. This voltage should be used for all subsequent total resistance measurements. Table 1: Total resistance test voltage Total Resistance, Nominal (ohm) Maximum Test Voltage (V) 1.0 3.0 10.0 30.0 100.0 V100 V1k V10k V100k 10 VR 100 FR 1k FR 10k FR 100k FR Standard Total Resistance R (ohm) Test Current 20mA 10mA 4mA 2mA 1mA 200μA 100μA 50μA 30μA R 100 FR 500 VR 1k VR 2k VR 50k VR 200k VR 1M VR 2M VR V100 F500 F1k F2k F50k F200k F1M F2M Sequence 1* +25 2 -15 3 Min. operating Temperature 4* +25 5 +65 6 Max. operating Temperature Temperature (°C) The following describes trimmer potentiometer testing conducted by Murata Manufacturing Co., Ltd. in accordance with MIL-R-22097 (military specification for variable resistors, non-wirewound) and MIL-STD-202 (test methods for electronic and electrical component parts). No. Test Methods Item Rx #1 #2 #3 Constant Current Source (Test current shown in Table 2) Calibration resistance AC Amplifier Oscilloscope Oscilloscope bandwidth :100Hz to 50kHz Rx : Trimmer Potentiometer e #2 #1 #3 E TCR= Z 106 (ppm/°C) R2 – R1 R1 (T2 – T1) vertical entry R50E.pdf Jul.23,2012 46 !Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc. • This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |