11 / 13 page ![]() 11 E3JM/E3JK ● Wiring Connecting and Wiring • We recommend connecting a cable with a conductor cross-section of 0.3 mm2 and an outer diameter of 6 to 8 mm. • Be sure to firmly tighten the cover in order to maintain waterproof and dustproof properties. The screw size of the conduit sockets is shown in the following table. Cable End Treatment Recommended Crimp Terminal Dimensions (Unit: mm) Note: Use terminals with insulation tube (recommended crimp terminal: 1.25 to 3.5). ● Others Terminal Protection Cover (Provided) The terminal protection cover is designed to improve safety by maintaining the sensitivity properties of the product and by preventing any contact with charged sections while it is being operated with the mode set to the timer mode. Mount the product as shown in the following diagram (mount the Through-beam Model on the Receiver side). ● Designing Power Reset Time The Sensor is ready to detect within 200 ms after it is turned ON. If the Sensor and load are connected to separate power supplies, be sure to turn ON the Sensor first. ● Wiring Connecting and Wiring DC SSR Output Models When using the DC SSR output model, the total of the load current for the Light-ON output (NO) and that for the Dark-ON (NC) should be 100 mA max. If the total exceeds 100 mA, the load short-circuit protection function will be activated (this function will be reset when the power of the Photoelectric Sensor is turned OFF). ● Others Ambient Conditions (Installation Area) The E3JM will malfunction if installed in the following places. • Places where the E3JM is exposed to a dusty environment. • Places where corrosive gases are produced. • Places where the E3JM is directly exposed to water, oil, or chemicals. Model Conduit socket thread size E3JM- @ PF1/2 Round type Fork type Power source Tc, Ta Tb Approx. 45 mm Approx. 55 mm Tightening nut (provided)* Washer (provided)* Rubber bushing (provided)* Adjust the four wires to the same length when the Ta output is to be used only. If both the Ta and Tb outputs are to be used, treat them as shown in the following diagram. Recommended example * These parts are not provided with models with a -US suffix. 10 max. 19 max. 3.6 dia. min. 7 max. 7 max. (After crimping) 10 max. 19 max. 3.6 dia. min. 7 max. 7 max. (After crimping) Terminal protection cover E3JM E3JK Items Common to E3JM and E3JK |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |