| 数据搜索系统,热门电子元器件搜索 |
|
3G5A2-RPT01-E 数据表(PDF) 34 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
3G5A2-RPT01-E 数据表(HTML) 34 Page - Omron Electronics LLC |
|
34 / 182 page ![]() 21 Mounting Locations The following table below summarizes the Units that can be mounted to CPU, Expansion CPU, Expansion I/O, and Slave Racks. For detailed information about the Units listed below, refer to the operation manual for the individual Unit. Unit CPU Rack Expansion CPU Rack Expansion I/O Racks Slave Racks (CV- or C-series) Remarks 16-/32-/64-point I/O Units Yes Yes Yes Yes --- Service Power Supplies Yes Yes Yes Yes --- Interrupt Input Units Yes Yes No No Up to 4 Units can be mounted. When mounting to the Expansion CPU Rack, set the rack number to 1. C500 Special I/O Units Yes Yes Yes Yes The following cannot be mounted to SYSMAC BUS/2 Slave Racks: NC103, NC221, NC222, CP131, FZ001, PID01, and MCC01. The following cannot be mounted to SYSMAC BUS Slave Racks: NC221, NC222, CT041, and FZ001. All other Special I/O Units can be mounted. Up to 8 of the following Units can be mounted: Analog Input, Analog Output, High-speed Counter, PID, Position Control, Magnetic Card, ASCII, ID Sensor, and Ladder Program I/O. Position Control Units, NC103-E, and PID Units use 2 slots. READ(190)/WRIT(191) cannot be used with Units mounted to SYSMAC BUS Slave Racks. BASIC Units Yes Yes No No Up to 16 CPU Bus Units can be d i h h PC i l di 2 Temperature Controller Data Link Unit Yes Yes No No used with each PC, including 2 Remote I/O Master Units for the CV500 or CVM1-CPU01-EV2 or 4 for the CV1000 CV2000 Personal Computer Units Yes Yes No No for the CV1000, CV2000, CVM1-CPU11-EV2, or CVM1-CPU21-EV2, up to a 4 SYSMAC NET Link Units Yes Yes No No CVM1-CPU21-EV2, u to a 4 each of the SYSMAC NET Link, SYSMAC LINK Units, Host Link U it Eth t U it d 1 SYSMAC LINK Units Yes Yes No No , Unit, or Ethernet Unit, and 1 CompoBus/D Master Unit. AP lC t U it SYSMAC BUS/2 Remote I/O Master Units Yes Yes No No A Personal Computer Unit requires 4 slots. Ethernet Units Yes Yes No No CompoBus/D Master Unit Yes Yes No No SYSMAC BUS Remote I/O Master Units Yes Yes Yes No Up to 4 Units can be mounted to a CV500 or CVM1-CPU01-EV2 and eight Units to a CV1000, CV2000, CVM1-CPU11-EV2, or CVM1-CPU21-EV2. SYSMAC BUS I/O Link Units Yes Yes Yes No I/O cannot be set to 16 input/16 output. System Configuration Section 2-1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |