| 数据搜索系统,热门电子元器件搜索 |
|
CS1W-RPT03 数据表(PDF) 16 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
CS1W-RPT03 数据表(HTML) 16 Page - Omron Electronics LLC |
|
16 / 70 page ![]() 4 Programmable Controllers SYSMAC CS1G/H ■ CS1 CPU Rack A CS1 CPU Rack consists of a CPU Unit, Power Supply Unit, and Configuration Units (Basic I/O Units, Special I/O Units, and CPU Bus Units). ● Required Units ● Types of Units In the SYSMAC CS Series, Units are classified into the following three types. The number of Racks differs depending on the type. Rack Unit name Required number of units CPU Rack CS1 CPU Backplane (CS1W-BC @@@) 1 Power Supply Unit 1 CPU Unit 1 Maximum Number of Configuration Units Varies by backplane model Type Appearance (example) Description Unit recognition method No. of Units Basic I/O Units Units with contact inputs and contact outputs. In the CS1 System, CS1 Basic I/O Units, C200H Basic I/O Units, and Group-2 High-density I/O Units are identified by their mounting positions (Rack and slot). The Units mounted must not exceed the maximum I/O capacity of the CPU Unit. Special I/O Units Special I/O Units provide more advanced functions than do Basic I/O Units, including I/O other than contact inputs and contact outputs. Examples of Special I/O Units are Analog I/O Units and High-speed Counter Units. They differ from CPU Bus Units (including Network Communications Units) in having a smaller area for exchanging data with the CPU Unit. Recognized by the CPU Unit according to the unit number (CS-series Special I/O Units: 0 to 95, C200J Special I/O Units: 0 to 9, or 0 to 15) set with the rotary switches on the front panel. CS-series Special I/O Units: 96 Units max.; C200H Special I/O Units: 10 or 16 Units max. (From 1 to 4 unit numbers are assigned per Unit, depending on the model of the Unit.) CPU Bus Units CPU Bus Units exchange data with the CPU Unit via the CPU Bus. Examples of CPU Bus Units are Network Communications Units and Serial Communications Units. They differ from Special I/O Units in having a larger area for exchanging data with the CPU Unit. Recognized by the CPU Unit according to the unit number (0 to F) set with the rotary switch on the front panel. A maximum of 16 Units can be mounted. PORT BUSY RUN ERR/ALM INH PRPHL MCPWR BKUP COMM SYSMAC CS1D-CPU67S PROGRAMMABLE CONTROLLER OPEN PERIPHERAL Basic I/O Units Special I/O Units CPU Bus Units Note: C200H Units cannot be used on the CPU Rack or Expansion Racks if a CS-series-only CPU Backplane (CS1W-BC @@3) is used. CS1 CPU Unit CS1G/H-CPU @@H CS1 CPU Backplane CS1W-BC @@@ (See note.) Power Supply Unit C200HW-P @@@@(@) CPU Rack CS1 Basic I/O Units C200H Basic I/O Units C200H Group-2 High-density I/O Units CS1 Special I/O Units C200H Special I/O Units CS1 CPU Bus Units |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |