Back Button E3S-R2E41 Datasheet HTML 3Page - Omron Electronics LLC E3S-R2E41 Datasheet HTML 4Page - Omron Electronics LLC E3S-R2E41 Datasheet HTML 5Page - Omron Electronics LLC E3S-R2E41 Datasheet HTML 6Page - Omron Electronics LLC E3S-R2E41 Datasheet HTML 7Page - Omron Electronics LLC E3S-R2E41 Datasheet HTML 8Page - Omron Electronics LLC E3S-R2E41 Datasheet HTML 9Page - Omron Electronics LLC E3S-R2E41 Datasheet HTML 10Page - Omron Electronics LLC E3S-R2E41 Datasheet HTML 11Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 15 page
background image
E3S
7
Adjustment Methods
● Adjusting the E3S-LS10XE4 Convergent-reflective
Sensor
1. Attach the distance adjustment scale as shown in the figure
and set it where the * mark is equal to the sensing distance.
2. Turn the distance adjuster until the red spot is at point
(center of the distance adjustment scale).
3. Remove the distance adjustment scale once the distance
has been adjusted. Put a sensing object in place, and then
adjust the sensitivity.
● Adjusting the E3S-LS20XE4 Convergent-reflective
Sensor
Adjustment Method 1
Use this method if the sensing object is more reflective than
the background.
1. Set the sensitivity adjuster to the center as shown in the
figure.
2. Turn the distance adjuster counterclockwise until it is fully
turned (L to S).
3. Position the sensing object.
4. Slowly turn the distance adjuster clockwise (S to L).
5. Eventually the LIGHT (red) indicator will light. Turning the
adjuster further will light the STABILITY (green) indicator.
Leave the distance adjuster at this level.
6. Adjust the sensitivity in this state.
Adjustment Method 2
Use this method if the background is more reflective than the
sensing object.
1. Set the sensitivity adjuster to the center as shown in the
figure.
2. Turn the distance adjuster clockwise until it is fully turned (S
to L).
3. Remove the sensing object.
4. Slowly turn the distance adjuster counterclockwise (L to S).
5. Eventually the LIGHT (red) indicator will light. Turning the
adjuster further will light the STABILITY (green) indicator.
6. Adjust the sensitivity in this state.
Distance adjustment scale
Align the distance adjustment scale
with the groove on the Sensor.
E3S-LS10XE4
A
Distance adjuster
Sensitivity adjustment
*
A
Distance adjuster
Sensing object
Center
Background
object
Distance adjuster
Sensing object
Center
Background
object



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com