| 数据搜索系统,热门电子元器件搜索 |
|
POE576U-4MP-N-R 数据表(PDF) 2 Page - Phihong USA Inc. |
|
|
|||||||||||||||||||||||||||||
POE576U-4MP-N-R 数据表(HTML) 2 Page - Phihong USA Inc. |
|
2 / 3 page ![]() POE576U-4MPN Characteristics WWW.PHIHONG.COM INPUT: Input Voltage Rating 100 to 240VAC Input Voltage Range 90 to 264VAC AC Input Current 9.0A (RMS) 90VAC at maximum load 4.25A (RMS) 230VAC at maximum load AC Input Frequency 47 to 63Hz Leakage Current 3.5mA maximum at 264VAC and 60Hz Max In-Rush Current: 30A for 115VAC at maximum load 60A for 230VAC at Maximum load (Cold Start at Ambient 25°C) OUTPUT: Total Output Power 95W per port 380W Maximum Total Power Ripple and Regulation 250mV maximum Efficiency 75% (typical) at maximum load, and 120VAC 60Hz Hold-Up Time 16mS min. 120VAC and maximum load Transient O/P Voltage Protection 60V maximum at switch on and off at any AC line Phase Turn-On Delay Time 20 sec maximum at maximum load, 120VAC 60Hz ENVIRONMENTAL Temperature Operation 0 to +40C Non-Operation -25 to +65C Humidity Operation 5 to 90% Non-Operation 5 to 90% EMC EN55022 Class A, FCC Class A with UTP cabling EN55022 Class B, FCC Class B with FTP cabling Isolation Test Primary to Secondary: 4242VDC for 1 minute Primary to Ground: 2121VDC for 1 minute Secondary to Ground: 2121VDC for 1 minute Immunity EN50082-1 ESD: EN61000-4-2 Level 3 RS: EN61000-4-3 Level 2 EFP: EN61000-4-4 Level 2 Surge: EN61000-4-5 Level 3 CS: EN61000-4-6 Level 2 Voltage Dips: EN61000-4-11 Harmonic: EN61000-3-2 Class A IEEE802.3af/at Interoperability If 25K Ohm is detect the unit operates in “IEEE802.3at mode” 33.6W 2 pair powering. 12.5K detection resistance required for full power. FEATURE: Cisco Legacy Detection No extern parts required for Legacy Devices: VoIP Phones: 7910, 7912, 7940, 7960 Access Points 350, 1100, 1200 Over-Voltage/Current, Short Circuit Protection Outputs equipped with short circuit protection and overload protection as per 802.3af specification except at maximum average current is 1.69A The output can be shorted permanently without damage Over Temperature Protection Automatic shutdown without damage Indicators Solid Green LED: Power detected “ON” Flashing Green: IEEE802.3at or (af) detected Yellow LED: Fault detected SNMPv2c management port Interface NIC interface for remote management via secure IP access Input Connector AC Input IEC320 C14 Output Connection 4-pair powering for full power Pins 3,6, 4,5(+) Pins 1,2, 7,8 (-) 2-pair powering for IEEE802.3at mode Pins 3,6(+) Pins 1,2 (-) Warranty 1 Year |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |